BORDEN-HENRYVILLE SCHOOL CORP
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
H1 3/13/2024 9:30:01 AM 10/13/2024 9:30:01 AM Annual Approved None Troy Boyd Export Inspection Report
H1 12/18/2023 8:33:01 AM 7/18/2024 8:33:01 AM Re-Inspection Approved None Troy Boyd Export Inspection Report
H1 12/14/2023 10:06:05 AM 7/14/2024 10:06:05 AM Re-Inspection Approved None Troy Boyd Export Inspection Report
H1 9/20/2023 8:47:00 AM Semi-Annual Out of Service
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
  • There is no brake certification, or the certification has expired or is not signed
  • Any exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
Troy Boyd Export Inspection Report
H1 3/22/2023 9:03:00 AM 4/20/2023 9:03:00 AM Annual Out of Service
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
  • Any exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
Troy Boyd Export Inspection Report
H1 11/14/2022 6:48:01 PM 6/14/2023 6:48:01 PM Re-Inspection Approved None Troy Boyd Export Inspection Report
H1 9/13/2022 9:27:00 AM 10/12/2022 9:27:00 AM Semi-Annual Out of Service
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
  • Any exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
Troy Boyd Export Inspection Report
H1 7/27/2022 9:29:01 AM 2/27/2023 9:29:01 AM Re-Inspection Approved None Troy Boyd Export Inspection Report
H1 4/22/2022 8:38:00 AM 5/21/2022 8:38:00 AM Annual Out of Service
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
  • Any exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
Troy Boyd Export Inspection Report
H1 12/1/2021 12:03:01 PM 7/1/2022 12:03:01 PM Re-Inspection Approved None Troy Boyd Export Inspection Report
H1 10/7/2021 9:49:00 AM 11/5/2021 9:49:00 AM Semi-Annual Out of Service
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
  • Any exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
Troy Boyd Export Inspection Report
H1 6/17/2021 1:55:01 PM 1/17/2022 1:55:01 PM Re-Inspection Approved None Troy Boyd Export Inspection Report
H1 6/16/2021 8:08:00 AM 7/15/2021 8:08:00 AM Annual Ordered Repaired
  • Any exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
Troy Boyd Export Inspection Report
H1 9/24/2020 8:01:01 AM 4/24/2021 8:01:01 AM Registration Approved None Troy Boyd Export Inspection Report
Go Back New Search