SOUTHWEST PARKE COMM SCH CORP
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
SWP14 6/21/2023 9:55:01 AM 9/30/2024 12:00:00 AM Annual Approved None Byron Goodman Export Inspection Report
SWP14 6/15/2022 12:47:01 PM 9/30/2023 12:00:00 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
SWP14 6/15/2022 12:46:00 PM Annual Out of Service
  • Warning lights fail to operate correctly
Byron Goodman Export Inspection Report
SWP14 11/5/2021 10:13:01 AM 9/30/2022 12:00:00 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
SWP14 6/17/2021 10:40:00 AM 7/16/2021 10:40:00 AM Annual Out of Service
  • LED Lights have 25% to 49% of pixels inoperable.
  • Any emergency window is too difficult to open
Byron Goodman Export Inspection Report
SWP14 7/21/2020 1:15:01 PM 9/30/2021 12:00:00 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
SWP14 4/16/2020 1:36:00 PM 5/15/2020 1:36:00 PM Annual Out of Service
  • LED Lights have 25% to 49% of pixels inoperable.
Byron Goodman Export Inspection Report
SWP14 2/27/2020 11:59:01 AM 9/30/2021 12:00:00 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
SWP14 6/19/2019 11:18:00 AM 7/18/2019 11:18:00 AM Annual Out of Service
  • The bus body has loose, damaged or improperly aligned body parts. These would include rivets, bolts, and body panels and/or rub rails
  • See Notes: Any defect inspector deems a violation not listed
Byron Goodman Export Inspection Report
SWP14 7/10/2018 9:29:01 AM 9/30/2019 12:00:00 AM Annual Approved None Byron Goodman Export Inspection Report
SWP14 7/21/2017 9:55:01 AM 9/30/2018 12:00:00 AM Re-Inspection Approved None Tyler VanNess Export Inspection Report
SWP14 7/21/2017 8:59:00 AM 8/19/2017 8:59:00 AM Annual Ordered Repaired
  • Any clearance light is missing, cracked, faded, wrong color, or inoperative
Tyler VanNess Export Inspection Report
SWP14 8/2/2016 10:34:01 AM 9/30/2017 12:00:00 AM Re-Inspection Approved None Tyler VanNess Export Inspection Report
SWP14 6/21/2016 11:13:00 AM Annual Out of Service
  • Any dome light is inoperative
Tyler VanNess Export Inspection Report
SWP14 7/13/2015 10:37:01 AM 9/30/2016 12:00:00 AM Annual Approved None Tyler VanNess Export Inspection Report
SWP14 7/9/2014 8:05:01 AM 9/30/2015 12:00:00 AM Annual Approved None Tyler VanNess Export Inspection Report
SWP14 6/12/2013 9:14:01 AM 9/30/2014 12:00:00 AM Re-Inspection Approved None Chuck Tharp Export Inspection Report
SWP14 6/12/2013 8:13:00 AM 7/11/2013 8:13:00 AM Annual Ordered Repaired
  • The first aid kit is not properly filled.
  • Emergency window instructions are illegible, missing, or not within 6 inches of the release handle
  • A defroster motor is inoperative at any speed.
Chuck Tharp Export Inspection Report
SWP14 3/15/2012 11:06:00 AM 9/30/2013 12:00:00 AM Registration Approved None Chuck Tharp Export Inspection Report
Go Back New Search