LEWIS-CASS SCHOOL CORPORATION
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
14 5/18/2023 10:54:01 AM 9/30/2024 12:00:00 AM Annual Approved None Randy McPike Export Inspection Report
14 5/18/2022 9:30:01 AM 9/30/2023 12:00:00 AM Annual Approved None Randy McPike Export Inspection Report
14 6/7/2021 10:35:01 AM 9/30/2022 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
14 6/7/2021 10:34:00 AM Annual Out of Service
  • There is no brake certification, or the certification has expired or is not signed
Randy McPike Export Inspection Report
14 5/21/2020 11:47:01 AM 9/30/2021 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
14 5/21/2020 11:47:00 AM 6/19/2020 11:47:00 AM Annual Ordered Repaired
  • The trash container is not secured to prevent movement and does not allow for easy removal and replacement
Randy McPike Export Inspection Report
14 5/17/2019 9:15:01 AM 9/30/2020 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
14 5/17/2019 9:15:00 AM 6/15/2019 9:15:00 AM Annual Ordered Repaired
  • The trash container is not secured to prevent movement and does not allow for easy removal and replacement
Randy McPike Export Inspection Report
14 5/23/2018 10:42:01 AM 9/30/2019 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
14 5/23/2018 10:42:00 AM 6/21/2018 10:42:00 AM Annual Ordered Repaired
  • Washers do not function properly in any manner
Randy McPike Export Inspection Report
14 6/14/2017 9:55:01 AM 9/30/2018 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
14 6/14/2017 9:54:00 AM 7/13/2017 9:54:00 AM Annual Ordered Repaired
  • The trash container is not secured to prevent movement and does not allow for easy removal and replacement
Randy McPike Export Inspection Report
14 6/10/2016 10:42:01 AM 9/30/2017 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
14 6/7/2016 9:39:00 AM 7/6/2016 9:39:00 AM Annual Ordered Repaired
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
Randy McPike Export Inspection Report
14 6/4/2015 9:39:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
14 6/4/2015 9:38:00 AM Annual Out of Service
  • There is no brake certification, or the certification has expired or is not signed
Randy McPike Export Inspection Report
14 3/6/2015 1:35:01 PM 9/30/2016 12:00:00 AM Registration Approved None Randy McPike Export Inspection Report
Go Back New Search