SOUTH GIBSON SCHOOL CORP.
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
8 11/8/2024 9:28:01 AM 6/8/2025 9:28:01 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
8 11/1/2024 9:12:00 AM 11/30/2024 9:12:00 AM Re-Inspection Ordered Repaired
  • A heater motor is not operating properly
Bradley MIller Export Inspection Report
8 10/30/2024 9:01:00 AM Semi-Annual Out of Service
  • Reservoir is empty
  • A heater motor is not operating properly
  • There is no brake certification, or the certification has expired or is not signed
Bradley MIller Export Inspection Report
8 8/21/2023 9:24:01 AM 9/30/2024 12:00:00 AM Annual Approved None Bradley MIller Export Inspection Report
8 9/9/2022 9:14:01 AM 9/30/2023 12:00:00 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
8 9/9/2022 9:14:00 AM 10/8/2022 9:14:00 AM Annual Ordered Repaired
  • Any seat back or bottom is loose
Bradley MIller Export Inspection Report
8 9/14/2021 9:30:01 AM 9/30/2022 12:00:00 AM Annual Approved None Bradley MIller Export Inspection Report
8 7/20/2020 9:24:01 AM 9/30/2021 12:00:00 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
8 7/20/2020 9:23:00 AM Re-Inspection Out of Service
  • Stop arm does not fully extend to a right angle to the bus
Bradley MIller Export Inspection Report
8 7/30/2019 9:49:01 AM 9/30/2020 12:00:00 AM Annual Approved None Bradley MIller Export Inspection Report
8 8/13/2018 8:54:01 AM 9/30/2019 12:00:00 AM Annual Approved None Bradley MIller Export Inspection Report
8 8/1/2017 10:00:18 AM 9/30/2018 12:00:00 AM Registration Approved None Bradley MIller Export Inspection Report
8 3/30/2016 8:31:01 AM 9/30/2017 12:00:00 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
8 3/29/2016 9:21:00 AM 4/27/2016 9:21:00 AM Annual Ordered Repaired
  • Any seat back or bottom is loose
  • The first aid kit is not complete: 3 packs of 16 1x3 adhesive strips, 1 scissor (4" min), 2 40"x40"x56" triangular bandages, 6 3"x3" gauze pads, 4 2"x4.1 yard rolls of gauze, 3 oval eye pads, 1 1"x5 yard of adhesive tape, 1 label instruction.
Bradley MIller Export Inspection Report
8 8/13/2015 4:12:14 PM 9/30/2016 12:00:00 AM Registration Approved None Bradley MIller Export Inspection Report
8 6/24/2014 10:44:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
8 6/24/2014 10:44:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
8 6/24/2014 9:55:00 AM Annual Out of Service
  • Any stop arm light is inoperative
  • There is no brake certification, the certification has expired, or is not signed within the six month requirement.
Bradley MIller Export Inspection Report
8 5/1/2013 9:23:01 AM 9/30/2014 12:00:00 AM Annual Approved None Chuck Tharp Export Inspection Report
8 1/23/2012 11:58:00 AM 9/30/2013 12:00:00 AM Annual Approved None Roger Cannon Export Inspection Report
Go Back New Search