| Bus # |
Inspection Date/Time |
Inspection Valid Until |
Inspection Type |
Inspection Status |
Violations |
Inspected By |
Reports |
| 612 |
5/22/2025 9:13:01 AM |
9/30/2026 12:00:00 AM |
Annual |
Approved |
None
|
Randy McPike |
|
| 612 |
5/20/2024 8:59:01 AM |
9/30/2025 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
| 612 |
5/16/2024 11:00:00 AM |
6/14/2024 11:00:00 AM |
Annual |
Ordered Repaired |
- A heater motor is not operating properly
|
Randy McPike |
|
| 612 |
5/19/2023 8:45:01 AM |
9/30/2024 12:00:00 AM |
Annual |
Approved |
None
|
Randy McPike |
|
| 612 |
5/17/2022 9:06:01 AM |
9/30/2023 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
| 612 |
5/17/2022 8:55:00 AM |
6/15/2022 8:55:00 AM |
Annual |
Ordered Repaired |
- If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
|
Randy McPike |
|
| 612 |
5/18/2021 8:11:01 AM |
9/30/2022 12:00:00 AM |
Annual |
Approved |
None
|
Randy McPike |
|
| 612 |
5/22/2020 9:59:01 AM |
9/30/2021 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
| 612 |
5/21/2020 8:58:00 AM |
6/19/2020 8:58:00 AM |
Annual |
Ordered Repaired |
- Any shock absorber is leaking fluid
- The first aid kit is not complete: One (1) package adhesive bandages; containing a total of sixteen (16) 1" x 3" bandages, 1 roll 1”x5yd, 1 blunt scissor, 6 3x3” gauze pads (sterile), 4 2”x5yd gauze stretch material (nonsterile), 3 oval eye pads (sterile), 2 triangular bandages, 1 instruction.
- If equipped the emergency warning buzzer does not sound
|
Randy McPike |
|
| 612 |
5/17/2019 9:42:01 AM |
9/30/2020 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
| 612 |
5/16/2019 8:51:00 AM |
6/14/2019 8:51:00 AM |
Annual |
Ordered Repaired |
- Any shock absorber is leaking fluid
|
Randy McPike |
|
| 612 |
5/24/2018 9:23:01 AM |
9/30/2019 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
| 612 |
5/24/2018 9:23:00 AM |
6/22/2018 9:23:00 AM |
Annual |
Ordered Repaired |
- Any dome light is inoperative
|
Randy McPike |
|
| 612 |
6/14/2017 9:15:01 AM |
9/30/2018 12:00:00 AM |
Annual |
Approved |
None
|
Randy McPike |
|
| 612 |
1/26/2017 3:13:01 PM |
9/30/2018 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
| 612 |
1/19/2017 11:20:00 AM |
2/17/2017 11:20:00 AM |
Registration |
Ordered Repaired |
- Not fully charged
- Any dome light is inoperative
|
Randy McPike |
|