| Bus # |
Inspection Date/Time |
Inspection Valid Until |
Inspection Type |
Inspection Status |
Violations |
Inspected By |
Reports |
| 3 |
1/14/2025 9:05:01 AM |
8/14/2025 9:05:01 AM |
Re-Inspection |
Approved |
None
|
Chris Kath |
|
| 3 |
1/13/2025 9:33:00 AM |
|
Annual |
Out of Service |
- There is no brake certification, or the certification has expired or is not signed
|
Nathan Hampton |
|
| 3 |
1/24/2024 10:00:01 AM |
9/30/2025 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Jeff Stone |
|
| 3 |
1/18/2024 10:43:00 AM |
|
Annual |
Out of Service |
- The bus with a body build date of January 1, 2006 or after is not equipped with the noise suppression switch. EXEMPTION Type A buses - w/out noise making devices other OEM accessories not including two-way, AM/FM, Satellite, or similar.
|
Nick Cox |
|
| 3 |
4/11/2023 10:35:01 AM |
9/30/2024 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Nick Cox |
|
| 3 |
4/11/2023 9:50:00 AM |
5/10/2023 9:50:00 AM |
Annual |
Ordered Repaired |
- There are loose items that would create a hazard. (Broom, Scraper, Items on dash etc.)
- There is debris in the bus. (needs cleaned/includes dirt)
|
Nick Cox |
|
| 3 |
3/16/2022 9:49:01 AM |
9/30/2023 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Joel Flores |
|
| 3 |
3/10/2022 10:34:00 AM |
|
Annual |
Out of Service |
- Excessive effort is needed to open the emergency door
|
Brandon Steffee |
|
| 3 |
8/31/2021 9:32:01 AM |
9/30/2022 12:00:00 AM |
Semi-Annual |
Approved |
None
|
Jeff Stone |
|
| 3 |
1/15/2021 8:59:01 AM |
9/30/2022 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Jeff Kastenschmidt |
|
| 3 |
11/24/2020 9:22:00 AM |
|
Re-Inspection |
Out of Service |
- See Notes: Any defect inspector deems a violation not listed
- Any emergency device is in poor condition
- The seat belt cutter does not have a full width handgrip, with a protective blade to minimize risk
- Does not have four combination red brake lamps, two with minimum 38 sq inch illuminated (7” round) and two with a minimum of 12 sq inches illuminated area(4” round), mounted on the rear of the body between the belt line and floor line
- There is unapproved glazing material installed in the bus
- There is no brake certification, or the certification has expired or is not signed
|
Jeff Kastenschmidt |
|
| 3 |
11/19/2020 3:31:00 PM |
|
Spot Checks |
Out of Service |
- The seat belt cutter does not have a full width handgrip, with a protective blade to minimize risk
- There is no brake certification, or the certification has expired or is not signed
- Any emergency device is in poor condition
- See Notes: Any defect inspector deems a violation not listed
- There is unapproved glazing material installed in the bus
|
Jeff Kastenschmidt |
|
| 3 |
6/26/2020 10:04:01 AM |
9/30/2021 12:00:00 AM |
Annual |
Approved |
None
|
Jeff Kastenschmidt |
|
| 3 |
3/13/2019 8:59:01 AM |
9/30/2020 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Alex Willis |
|
| 3 |
3/11/2019 9:17:00 AM |
4/9/2019 9:17:00 AM |
Annual |
Ordered Repaired |
- Any dome light is inoperative
|
John Pang |
|
| 3 |
3/19/2018 9:19:01 AM |
9/30/2019 12:00:00 AM |
Annual |
Approved |
None
|
John Pang |
|
| 3 |
3/21/2017 10:15:01 AM |
9/30/2018 12:00:00 AM |
Annual |
Approved |
None
|
John Pang |
|
| 3 |
3/11/2016 9:37:01 AM |
9/30/2017 12:00:00 AM |
Annual |
Approved |
None
|
Larry Gershanoff |
|
| 3 |
4/13/2015 10:11:01 AM |
9/30/2016 12:00:00 AM |
Annual |
Approved |
None
|
Edwin Davis |
|
| 3 |
8/12/2014 9:43:01 AM |
9/30/2015 12:00:00 AM |
Registration |
Approved |
None
|
Alex Willis |
|