GOSHEN COMMUNITY SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
19 6/24/2024 9:25:01 AM 9/30/2025 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
19 6/14/2023 9:31:01 AM 9/30/2024 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
19 6/8/2022 10:54:01 AM 9/30/2023 12:00:00 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
19 6/8/2022 10:23:00 AM 7/7/2022 10:23:00 AM Re-Inspection Ordered Repaired
  • Prohibited area sign is missing or obscured
Wes Rowlader Export Inspection Report
19 6/8/2022 9:36:00 AM Annual Out of Service
  • Any brake line or hose is abraded (chafed), cracked, bulging or leaking (leaking at other than a proper connection).
  • Prohibited area sign is missing or obscured
Wes Rowlader Export Inspection Report
19 6/16/2021 8:35:01 AM 9/30/2022 12:00:00 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
19 6/15/2021 9:07:00 AM Annual Out of Service
  • Any brake line or hose is abraded (chafed), cracked, bulging or leaking (leaking at other than a proper connection).
  • A dripping oil or fluid leak
Wes Rowlader Export Inspection Report
19 6/24/2020 9:25:01 AM 9/30/2021 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
19 7/25/2019 10:01:01 AM 9/30/2020 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
19 6/26/2018 10:47:01 AM 9/30/2019 12:00:00 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
19 6/26/2018 10:47:00 AM 7/25/2018 10:47:00 AM Annual Ordered Repaired
  • Reservoir is empty
Wes Rowlader Export Inspection Report
19 6/28/2017 11:22:01 AM 9/30/2018 12:00:00 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
19 6/28/2017 10:19:00 AM 7/27/2017 10:19:00 AM Re-Inspection Ordered Repaired
  • Air leak at proper connection
Wes Rowlader Export Inspection Report
19 6/28/2017 10:19:00 AM 7/27/2017 10:19:00 AM Annual Ordered Repaired
  • The seat belt cutter is not secured
  • Air leak at proper connection
Wes Rowlader Export Inspection Report
19 7/8/2016 10:48:01 AM 9/30/2017 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
19 7/10/2015 9:21:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Brian Bills Export Inspection Report
19 7/10/2015 9:21:01 AM 9/30/2016 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
19 7/8/2014 9:54:01 AM 9/30/2015 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
19 2/19/2013 2:08:01 PM 9/30/2014 12:00:00 AM Registration Approved None Brian Bills Export Inspection Report
Go Back New Search