NORTH WHITE SCHOOL CORPORATION
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
12 4/18/2024 9:45:01 AM 11/18/2024 9:45:01 AM Re-Inspection Approved None Nate King Export Inspection Report
12 4/18/2024 9:45:00 AM 5/17/2024 9:45:00 AM Annual Ordered Repaired
  • LED type lights have 25% to 49% of the pixels inoperable in any one light
  • LED type lights have 25% to 49% pixels inoperable in any one light. (NOTE: one letter in the word “STOP” equals one light
Nate King Export Inspection Report
12 5/18/2023 9:16:01 AM 9/30/2024 12:00:00 AM Re-Inspection Approved None Nate King Export Inspection Report
12 5/18/2023 9:15:00 AM 6/16/2023 9:15:00 AM Annual Ordered Repaired
  • LED type lights have 25% to 49% pixels inoperable in any one light. (NOTE: one letter in the word “STOP” equals one light
  • Any shock absorber is leaking fluid
Nate King Export Inspection Report
12 4/27/2022 10:10:01 AM 9/30/2023 12:00:00 AM Re-Inspection Approved None Nate King Export Inspection Report
12 4/27/2022 10:10:00 AM 5/26/2022 10:10:00 AM Annual Ordered Repaired
  • LED type lights have 25% to 49% pixels inoperable in any one light. (NOTE: one letter in the word “STOP” equals one light
Nate King Export Inspection Report
12 4/20/2021 9:33:01 AM 9/30/2022 12:00:00 AM Annual Approved None Nate King Export Inspection Report
12 8/6/2019 12:30:14 PM 9/30/2020 12:00:00 AM Registration Approved None Nate King Export Inspection Report
12 4/23/2018 10:56:01 AM 9/30/2019 12:00:00 AM Annual Approved None Nate King Export Inspection Report
12 5/17/2017 8:46:01 AM 9/30/2018 12:00:00 AM Re-Inspection Approved None Nate King Export Inspection Report
12 5/17/2017 8:46:00 AM Annual Out of Service
  • There is no brake certification, or the certification has expired or is not signed
Nate King Export Inspection Report
12 5/4/2016 10:30:01 AM 9/30/2017 12:00:00 AM Re-Inspection Approved None Nate King Export Inspection Report
12 5/4/2016 10:30:00 AM 6/2/2016 10:30:00 AM Annual Ordered Repaired
  • Any front turn signal does not function properly
  • LED type lights have 25% to 49% pixels inoperable in any one light. (NOTE: one letter in the word "STOP" equals one light
Nate King Export Inspection Report
12 3/24/2015 11:51:01 AM 9/30/2016 12:00:00 AM Annual Approved None Nate King Export Inspection Report
12 5/27/2014 10:26:01 AM 9/30/2015 12:00:00 AM Annual Approved None Nate King Export Inspection Report
12 5/20/2013 10:16:01 AM 9/30/2014 12:00:00 AM Annual Approved None Nate King Export Inspection Report
12 7/10/2012 8:48:00 AM 9/30/2013 12:00:00 AM Annual Approved None Joel Flores Export Inspection Report
Go Back New Search