Bus # |
Inspection Date/Time |
Inspection Valid Until |
Inspection Type |
Inspection Status |
Violations |
Inspected By |
Reports |
1958 |
5/14/2024 11:53:00 AM |
|
Post-Crash Inspection |
O |
- See Notes: Any defect inspector deems a violation not listed
- Any tire is flat
- See Notes: Any defect inspector deems a violation not listed
- Both lamps are inoperative on low beam
- Both lamps are inoperative on high beam
- Rims are bent or loose
- The bus body has loose, damaged or improperly aligned body parts. These would include rivets, bolts, and body panels and/or rub rails
- There is body damage which could cause injury to persons near the bus (e.g. jagged metal edges, etc.)((Exigent circumstance can be taken into consideration to allow the bus to return home in a post crash inspection if bus is out of its district)).
- The communication system is mounted in a manner that would cause injuries in the event of a sudden stop
- Frame is deteriorated, cracked, broken or severely bent
- Any front turn signal does not function properly
- LED lights have 50% or more of the pixels inoperable
- Defroster is inoperative
- Any glass or glazing is broken through or missing
- Does not conform to original specifications
- See Notes: Any defect inspector deems a violation not listed
- The grill is missing
|
Byron Goodman |
|
2289 |
5/14/2024 11:17:00 AM |
|
Annual |
O |
- Any glass or glazing is cracked, chipped, clouded or distorted badly enough to prohibit a clear view from within the bus
|
Byron Goodman |
|
1078 |
3/26/2024 10:49:00 AM |
|
Annual |
O |
- There is fuel leaking from any point on in the fuel system
|
Byron Goodman |
|
1222 |
2/27/2024 10:33:00 AM |
|
Re-Inspection |
O |
- Any crossmember is rusted sufficiently to weaken floor supports
|
Byron Goodman |
|
1158 |
2/6/2024 10:47:00 AM |
|
Annual |
O |
- Is no audible signal when the emergency door is open and ignition switch is on
|
Byron Goodman |
|
933 |
10/22/2020 3:51:01 PM |
9/30/2021 12:00:00 AM |
Re-Inspection |
A |
None
|
Byron Goodman |
|
941 |
7/29/2020 9:53:01 AM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
939 |
7/29/2020 9:36:01 AM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
934 |
7/21/2020 9:16:01 PM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
931 |
3/13/2020 1:15:01 PM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
935 |
3/4/2020 10:40:01 AM |
9/30/2021 12:00:00 AM |
Re-Inspection |
A |
None
|
Byron Goodman |
|
942 |
3/3/2020 10:50:01 AM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
938 |
3/3/2020 10:27:01 AM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
930 |
2/25/2020 11:08:01 AM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
932 |
2/25/2020 10:30:01 AM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
945 |
2/25/2020 10:25:01 AM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
944 |
2/18/2020 10:20:01 AM |
9/30/2021 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1030 |
4/14/2021 12:41:01 PM |
9/30/2022 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1025 |
4/13/2021 12:05:01 PM |
9/30/2022 12:00:00 AM |
Re-Inspection |
A |
None
|
Byron Goodman |
|
1033 |
4/6/2021 10:42:01 AM |
9/30/2022 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1021 |
3/30/2021 10:07:01 AM |
9/30/2022 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1029 |
3/30/2021 9:55:01 AM |
9/30/2022 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1031 |
3/2/2021 11:44:01 AM |
9/30/2022 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1028 |
3/2/2021 11:16:01 AM |
9/30/2022 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1027 |
1/12/2021 11:21:01 AM |
9/30/2022 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1026 |
1/12/2021 11:02:01 AM |
9/30/2022 12:00:00 AM |
Annual |
A |
None
|
Byron Goodman |
|
1023 |
3/8/2022 11:47:01 AM |
10/8/2022 11:47:01 AM |
Annual |
A |
None
|
Byron Goodman |
|
1035 |
9/29/2022 11:37:01 AM |
4/29/2023 11:37:01 AM |
Semi-Annual |
A |
None
|
Byron Goodman |
|
1038 |
9/29/2022 11:37:01 AM |
4/29/2023 11:37:01 AM |
Semi-Annual |
A |
None
|
Byron Goodman |
|
2132 |
4/4/2023 11:02:00 AM |
5/3/2023 11:02:00 AM |
Annual |
O |
- The bus body has loose, damaged or improperly aligned body parts. These would include rivets, bolts, and body panels and/or rub rails
|
Byron Goodman |
|
1713 |
4/25/2023 11:27:00 AM |
5/24/2023 11:27:00 AM |
Annual |
O |
- If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
|
Byron Goodman |
|
1964 |
5/23/2023 11:39:00 AM |
6/21/2023 11:39:00 AM |
Annual |
O |
- A heater motor is not operating properly
|
Byron Goodman |
|
1387 |
6/6/2023 10:28:00 AM |
7/5/2023 10:28:00 AM |
Annual |
O |
- Any front turn signal does not function properly
|
Byron Goodman |
|
1024 |
1/25/2023 10:25:01 AM |
8/25/2023 10:25:01 AM |
Annual |
A |
None
|
Byron Goodman |
|
1043 |
1/25/2023 10:32:01 AM |
8/25/2023 10:32:01 AM |
Annual |
A |
None
|
Byron Goodman |
|
1041 |
1/25/2023 10:32:01 AM |
8/25/2023 10:32:01 AM |
Re-Inspection |
A |
None
|
Byron Goodman |
|
1076 |
1/25/2023 10:33:01 AM |
8/25/2023 10:33:01 AM |
Annual |
A |
None
|
Byron Goodman |
|
1145 |
1/25/2023 10:34:01 AM |
8/25/2023 10:34:01 AM |
Annual |
A |
None
|
Byron Goodman |
|
1148 |
1/25/2023 10:35:01 AM |
8/25/2023 10:35:01 AM |
Annual |
A |
None
|
Byron Goodman |
|
1146 |
1/25/2023 10:35:01 AM |
8/25/2023 10:35:01 AM |
Annual |
A |
None
|
Byron Goodman |
|