FRANKLIN COUNTY COMM. SCH CORP
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
33 5/9/2024 9:08:01 AM 9/30/2025 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 5/1/2023 9:03:01 AM 9/30/2024 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 4/21/2022 9:18:01 AM 9/30/2023 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 5/13/2021 9:05:01 AM 9/30/2022 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 7/6/2020 9:22:01 AM 9/30/2021 12:00:00 AM Annual Approved None Dan Elmore Export Inspection Report
33 4/30/2019 9:22:01 AM 9/30/2020 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 4/9/2018 9:48:01 AM 9/30/2019 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 9/5/2017 11:46:01 AM 9/30/2018 12:00:00 AM Registration Approved None Chris Clark Export Inspection Report
33 4/24/2017 10:02:01 AM 9/30/2018 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 5/9/2016 9:53:01 AM 9/30/2017 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 7/29/2015 1:42:01 PM 9/30/2016 12:00:00 AM Registration Approved None Chris Clark Export Inspection Report
33 5/14/2015 9:19:01 AM 9/30/2016 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 1/22/2015 12:33:01 PM 9/30/2016 12:00:00 AM Registration Approved None Chris Clark Export Inspection Report
33 6/2/2014 8:06:01 AM 9/30/2015 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
33 4/2/2014 10:01:01 AM 9/30/2015 12:00:00 AM Spot Checks Approved None Chris Clark Export Inspection Report
33 3/7/2014 1:25:00 PM 4/5/2014 1:25:00 PM Spot Checks Ordered Repaired
  • The first aid kit is not properly displayed.
  • The first aid kit is not properly filled.
  • Heater motor is not operating properly.
Chris Clark Export Inspection Report
33 6/21/2013 8:47:01 AM 9/30/2014 12:00:00 AM Re-Inspection Approved None Chris Clark Export Inspection Report
33 5/10/2013 10:43:00 AM Annual Out of Service
  • Emergency window instructions are illegible, missing, or not within 6 inches of the release handle
Chris Clark Export Inspection Report
33 7/25/2012 12:01:00 PM 9/30/2013 12:00:00 AM Re-Inspection Approved None Dave Whitinger Export Inspection Report
33 7/25/2012 8:38:00 AM 8/23/2012 8:38:00 AM Annual Ordered Repaired
  • A light shall be placed inside the bus over the special service door, and shall be operated from the door area to adequately illuminate the special service door area
  • There is body damage which could cause injury to persons near the bus (i.e. jagged metal edges, etc.).
  • There are unauthorized attachments to the exterior of the bus.
Dave Whitinger Export Inspection Report
Go Back New Search