Bus # |
Inspection Date/Time |
Inspection Valid Until |
Inspection Type |
Inspection Status |
Violations |
Inspected By |
Reports |
3 |
3/19/2024 10:27:01 AM |
9/30/2025 12:00:00 AM |
Annual |
Approved |
None
|
Nathan Hampton |
|
3 |
9/7/2023 10:55:01 AM |
9/30/2024 12:00:00 AM |
Registration |
Approved |
None
|
Nick Cox |
|
3 |
3/16/2023 9:05:01 AM |
10/16/2023 9:05:01 AM |
Re-Inspection |
Approved |
None
|
Brandon Steffee |
|
3 |
3/15/2023 9:35:00 AM |
|
Annual |
Out of Service |
- Power steering unit leaks at any point
- There is fuel leaking from any point on in the fuel system
|
Joel Flores |
|
3 |
9/20/2022 9:41:01 AM |
4/20/2023 9:41:01 AM |
Re-Inspection |
Approved |
None
|
Jeff Stone |
|
3 |
9/20/2022 9:34:00 AM |
10/19/2022 9:34:00 AM |
Semi-Annual |
Ordered Repaired |
- Power steering unit leaks at any point
|
Jeff Stone |
|
3 |
4/13/2022 9:33:01 AM |
11/13/2022 9:33:01 AM |
Re-Inspection |
Approved |
None
|
Jeff Stone |
|
3 |
4/13/2022 9:32:00 AM |
5/12/2022 9:32:00 AM |
Annual |
Ordered Repaired |
- LED type lights have 25% or more of the pixels inoperable in any one light
|
Jeff Stone |
|
3 |
8/26/2021 10:24:01 AM |
3/26/2022 10:24:01 AM |
Semi-Annual |
Approved |
None
|
Rob Hawkins |
|
3 |
3/25/2021 11:17:01 AM |
10/25/2021 11:17:01 AM |
Re-Inspection |
Approved |
None
|
Jeff Kastenschmidt |
|
3 |
3/25/2021 10:01:00 AM |
4/23/2021 10:01:00 AM |
Annual |
Ordered Repaired |
- Not securely mounted
- Power steering unit leaks at any point
|
Jeff Kastenschmidt |
|
3 |
4/30/2020 9:13:01 AM |
11/30/2020 9:13:01 AM |
Annual |
Approved |
None
|
Jeff Stone |
|
3 |
3/5/2019 9:34:01 AM |
9/30/2020 12:00:00 AM |
Annual |
Approved |
None
|
Alex Willis |
|
3 |
3/13/2018 10:23:01 AM |
9/30/2019 12:00:00 AM |
Annual |
Approved |
None
|
John Pang |
|
3 |
3/14/2017 12:08:01 PM |
9/30/2018 12:00:00 AM |
Annual |
Approved |
None
|
John Pang |
|
3 |
3/8/2016 9:32:01 AM |
9/30/2017 12:00:00 AM |
Annual |
Approved |
None
|
Edwin Davis |
|
3 |
3/25/2015 9:57:01 AM |
9/30/2016 12:00:00 AM |
Annual |
Approved |
None
|
Alex Willis |
|
3 |
3/26/2014 9:27:01 AM |
9/30/2015 12:00:00 AM |
Annual |
Approved |
None
|
Edwin Davis |
|
3 |
4/10/2013 11:22:01 AM |
9/30/2014 12:00:00 AM |
Re-Inspection |
Approved |
None
|
John Pang |
|
3 |
4/10/2013 11:22:00 AM |
5/9/2013 11:22:00 AM |
Annual |
Ordered Repaired |
- Required back-up lights do not function.
|
John Pang |
|
3 |
3/27/2012 10:00:00 AM |
9/30/2013 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Chris Kath |
|
3 |
3/26/2012 11:21:00 AM |
4/24/2012 11:21:00 AM |
Annual |
Ordered Repaired |
- Led lights have 25% up to 49 % of pixels inoperable
|
Chris Kath |
|