DUNELAND SCHOOL CORPORATION
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
5 6/22/2023 7:29:01 AM 9/30/2024 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
5 6/22/2022 7:04:01 AM 9/30/2023 12:00:00 AM Annual Approved None Tim Grayson Export Inspection Report
5 6/28/2021 8:21:01 AM 9/30/2022 12:00:00 AM Annual Approved None Tim Grayson Export Inspection Report
5 9/8/2020 9:27:01 AM 9/30/2021 12:00:00 AM Registration Approved None Nathan Sherer Export Inspection Report
5 6/23/2020 10:34:01 AM 1/23/2021 10:34:01 AM Annual Approved None Tim Grayson Export Inspection Report
5 6/22/2020 11:24:01 AM 1/22/2021 11:24:01 AM Annual Approved None Nathan Sherer Export Inspection Report
5 6/20/2019 8:24:01 AM 9/30/2020 12:00:00 AM Annual Approved None Tim Grayson Export Inspection Report
5 7/17/2018 9:39:01 AM 9/30/2019 12:00:00 AM Re-Inspection Approved None Tim Grayson Export Inspection Report
5 7/16/2018 8:13:01 AM 9/30/2019 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
5 7/12/2017 8:23:01 AM 9/30/2018 12:00:00 AM Annual Approved None Tim Grayson Export Inspection Report
5 6/29/2016 7:57:01 AM 9/30/2017 12:00:00 AM Annual Approved None Dale Morgan Export Inspection Report
5 7/1/2015 9:32:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Dale Morgan Export Inspection Report
5 7/1/2015 8:33:00 AM 7/30/2015 8:33:00 AM Annual Ordered Repaired
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
Dale Morgan Export Inspection Report
5 6/16/2014 9:25:01 AM 9/30/2015 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
5 6/12/2013 9:54:01 AM 9/30/2014 12:00:00 AM Annual Approved None David Eggers Export Inspection Report
5 6/27/2012 9:39:00 AM Re-Inspection Out of Service
  • The first aid kit is not properly filled in accordance with the '24 Unit Kit'.
David Eggers Export Inspection Report
5 6/27/2012 9:39:00 AM 9/30/2013 12:00:00 AM Re-Inspection Approved None David Eggers Export Inspection Report
5 6/27/2012 8:08:00 AM 9/30/2013 12:00:00 AM Annual Approved None David Eggers Export Inspection Report
Go Back New Search