AUXILIO SERVICES (MUNCIE)
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
M9 5/30/2023 9:32:01 AM 9/30/2024 12:00:00 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
M9 5/30/2023 9:31:00 AM Annual Out of Service
  • There is body damage which could cause injury to persons near the bus (e.g. jagged metal edges, etc.)((Exigent circumstance can be taken into consideration to allow the bus to return home in a post crash inspection if bus is out of its district)).
  • There are any loose, broken, or missing mountings
Steve Spallinger Export Inspection Report
M9 5/5/2022 10:13:01 AM 9/30/2023 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
M9 5/5/2022 9:49:00 AM 6/3/2022 9:49:00 AM Annual Ordered Repaired
  • LED type lights have 25% to 49% pixels inoperable in any one light. (NOTE: one letter in the word “STOP” equals one light
Jamie Hotchkiss Export Inspection Report
M9 5/20/2021 10:03:01 AM 9/30/2022 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
M9 5/28/2020 10:06:01 AM 9/30/2021 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
M9 7/18/2019 10:57:01 AM 9/30/2020 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
M9 6/4/2019 8:43:00 AM 7/3/2019 8:43:00 AM Re-Inspection Out of Service
  • There is air leak at the stop arm air bladder that does not affect the air braking system
Jamie Hotchkiss Export Inspection Report
M9 5/28/2019 8:56:00 AM 6/26/2019 8:56:00 AM Annual Ordered Repaired
  • Step-well light is missing or inoperative
  • There is air leak at the stop arm air bladder that does not affect the air braking system
Jamie Hotchkiss Export Inspection Report
M9 5/15/2018 11:02:01 AM 9/30/2019 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
M9 10/4/2017 1:36:01 PM 9/30/2018 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
M9 10/2/2017 1:34:24 PM 10/31/2017 1:34:24 PM Registration Ordered Repaired
  • There is air leak at the stop arm air bladder that does not affect the air braking system
Chris Kath Export Inspection Report
Go Back New Search