Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
30 11/3/2023 9:47:01 AM 6/3/2024 9:47:01 AM Semi-Annual Approved None Steve Spallinger Export Inspection Report
30 6/23/2023 11:04:01 AM 1/23/2024 11:04:01 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
30 6/23/2023 11:04:00 AM 7/22/2023 11:04:00 AM Annual Ordered Repaired
  • Fan is loosely attached or wobbles
Steve Spallinger Export Inspection Report
30 12/19/2022 9:56:01 AM 7/19/2023 9:56:01 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
30 12/12/2022 11:29:00 AM 1/10/2023 11:29:00 AM Semi-Annual Ordered Repaired
  • Upholstery or padding is ripped, torn, or improperly repaired
Steve Spallinger Export Inspection Report
30 6/29/2022 11:22:01 AM 1/29/2023 11:22:01 AM Annual Approved None Steve Spallinger Export Inspection Report
30 6/10/2021 10:44:01 AM 9/30/2022 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
30 6/10/2021 9:37:00 AM Annual Out of Service
  • There is fuel leaking from any point on in the fuel system
Jamie Hotchkiss Export Inspection Report
30 6/19/2020 8:58:01 AM 9/30/2021 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
30 6/8/2020 12:02:00 PM Annual Out of Service
  • Wiper blades fail to contact the windshield properly
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Jamie Hotchkiss Export Inspection Report
30 6/14/2019 8:57:01 AM 9/30/2020 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
30 6/14/2019 8:56:00 AM 7/13/2019 8:56:00 AM Annual Ordered Repaired
  • Step-well light is missing or inoperative
Jamie Hotchkiss Export Inspection Report
30 5/31/2018 10:56:01 AM 9/30/2019 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
30 6/7/2017 11:43:01 AM 9/30/2018 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
30 5/31/2017 10:19:00 AM Annual Out of Service
  • Any brake line or hose is abraded (chafed), cracked, bulging or leaking (leaking at other than a proper connection).
Jamie Hotchkiss Export Inspection Report
30 6/1/2016 10:02:01 AM 9/30/2017 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
30 7/23/2015 10:33:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
30 6/4/2015 8:58:00 AM Annual Out of Service
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
Jamie Hotchkiss Export Inspection Report
30 6/3/2014 11:26:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
30 6/3/2014 11:25:00 AM 7/2/2014 11:25:00 AM Annual Ordered Repaired
  • If required, positive door opening device is missing or fails to operate properly.
Jamie Hotchkiss Export Inspection Report
30 7/30/2013 8:09:01 AM 9/30/2014 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
30 6/17/2013 10:13:00 AM Annual Out of Service
  • Washers do not function properly in any manner
Jamie Hotchkiss Export Inspection Report
30 6/28/2012 9:24:00 AM 9/30/2013 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
30 6/14/2012 9:23:00 AM 7/13/2012 9:23:00 AM Annual Ordered Repaired
  • One (1) taillight or one (1) brake light does not function
  • Any body clamp is loose.
Randy McPike Export Inspection Report