Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
1441 1/30/2024 10:30:01 AM 9/30/2025 12:00:00 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
1441 1/30/2024 10:30:00 AM 2/28/2024 10:30:00 AM Re-Inspection Ordered Repaired
  • There is debris in the bus. (needs cleaned/includes dirt)
Byron Goodman Export Inspection Report
1441 3/8/2023 12:07:01 PM 9/30/2024 12:00:00 AM Annual Approved None Byron Goodman Export Inspection Report
1441 5/6/2022 9:43:40 AM 9/30/2023 12:00:00 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
1441 3/29/2022 8:18:00 AM Annual Out of Service
  • Tires are cut, weathered, cracked, have lumps, or breaks that expose the cord
Byron Goodman Export Inspection Report
1441 5/13/2021 11:06:01 PM 9/30/2022 12:00:00 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
1441 4/20/2021 10:34:00 AM 5/19/2021 10:34:00 AM Annual Out of Service
  • The bus body has loose, damaged or improperly aligned body parts. These would include rivets, bolts, and body panels and/or rub rails
Byron Goodman Export Inspection Report
1441 2/4/2020 11:03:01 AM 9/30/2021 12:00:00 AM Annual Approved None Byron Goodman Export Inspection Report
1441 4/23/2019 11:09:01 AM 9/30/2020 12:00:00 AM Annual Approved None Byron Goodman Export Inspection Report
1441 3/6/2018 10:43:01 AM 9/30/2019 12:00:00 AM Annual Approved None Byron Goodman Export Inspection Report
1441 1/10/2017 8:44:01 AM 9/30/2018 12:00:00 AM Annual Approved None Tyler VanNess Export Inspection Report
1441 1/12/2016 9:27:01 AM 9/30/2017 12:00:00 AM Annual Approved None Tyler VanNess Export Inspection Report
1441 5/11/2015 9:02:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Tyler VanNess Export Inspection Report
1441 5/11/2015 9:02:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Tyler VanNess Export Inspection Report
1441 5/11/2015 8:56:00 AM Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Tyler VanNess Export Inspection Report
1441 5/11/2015 8:56:00 AM Re-Inspection Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Tyler VanNess Export Inspection Report
1441 7/31/2014 11:23:01 AM 9/30/2015 12:00:00 AM Registration Approved None Tyler VanNess Export Inspection Report
Go Back New Search