NORTHERN WELLS COMM. SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
21 1/17/2023 10:03:01 AM 8/17/2023 10:03:01 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
21 12/20/2022 9:28:00 AM Semi-Annual Out of Service
  • There is body damage which could cause injury to persons near the bus (e.g. jagged metal edges, etc.)((Exigent circumstance can be taken into consideration to allow the bus to return home in a post crash inspection if bus is out of its district)).
  • There is fuel leaking from any point on in the fuel system
  • Any required instrument or gauge is inoperative. (Speedometer, Odometer, Fuel Gauge, High beam, Brake indicator light or gauge, air pressure gauge, brake warning light, DEF Gauge)
  • See Notes: Any defect inspector deems a violation not listed
  • The first aid kit is not complete: One (1) package adhesive bandages; containing a total of sixteen (16) 1" x 3" bandages, 1 roll 1”x5yd, 1 blunt scissor, 6 3x3” gauze pads (sterile), 4 2”x5yd gauze stretch material (nonsterile), 3 oval eye pads (sterile), 2 triangular bandages, 1 instruction.
Steve Spallinger Export Inspection Report
21 8/9/2022 9:11:01 AM 3/9/2023 9:11:01 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
21 7/14/2022 11:52:00 AM 8/12/2022 11:52:00 AM Annual Ordered Repaired
  • Any push-rod travel measures less than 1/4 inch beyond the readjustment limit
  • One (1) taillight or one (1) brake light does not function
  • Required back-up lights do not function.
  • See Notes: Any defect inspector deems a violation not listed
Steve Spallinger Export Inspection Report
21 11/2/2021 9:32:01 AM 6/2/2022 9:32:01 AM Semi-Annual Approved None Jamie Hotchkiss Export Inspection Report
21 6/3/2021 9:29:01 AM 1/3/2022 9:29:01 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
21 10/21/2020 10:36:01 AM 5/21/2021 10:36:01 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
21 10/21/2020 10:35:00 AM 11/19/2020 10:35:00 AM Semi-Annual Ordered Repaired
  • The trash container is greater than a fourteen (14) quart capacity
Jamie Hotchkiss Export Inspection Report
21 6/10/2020 12:34:01 PM 1/10/2021 12:34:01 PM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
21 5/18/2020 9:09:00 AM Annual Out of Service
  • The trash container is greater than a fourteen (14) quart capacity
  • Warning lights fail to operate correctly
Jamie Hotchkiss Export Inspection Report
21 5/18/2020 9:09:00 AM Re-Inspection Out of Service
  • Warning lights fail to operate correctly
Jamie Hotchkiss Export Inspection Report
21 1/16/2020 10:06:01 AM 8/16/2020 10:06:01 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
21 1/16/2020 9:32:00 AM Semi-Annual Out of Service
  • Any seat back or bottom is loose
  • Stop arm does not fully extend to a right angle to the bus
Jamie Hotchkiss Export Inspection Report
21 7/24/2019 9:21:01 AM 2/24/2020 9:21:01 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
21 1/8/2019 9:23:01 AM 8/8/2019 9:23:01 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
21 1/8/2019 9:07:00 AM 2/6/2019 9:07:00 AM Semi-Annual Ordered Repaired
  • Any hanger, clamp or bracket is missing, loose or broken
  • The trash container is greater than a fourteen (14) quart capacity
  • The trash container is not secured to prevent movement and does not allow for easy removal and replacement
Jamie Hotchkiss Export Inspection Report
21 1/8/2019 9:07:00 AM 2/6/2019 9:07:00 AM Re-Inspection Ordered Repaired
  • Any hanger, clamp or bracket is missing, loose or broken
Jamie Hotchkiss Export Inspection Report
21 7/25/2018 8:02:01 AM 2/25/2019 8:02:01 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
21 7/24/2018 9:47:00 AM Annual Out of Service
  • Required back-up lights do not function.
  • Any tire is flat
Jamie Hotchkiss Export Inspection Report
21 8/17/2017 12:42:59 PM 9/30/2018 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
21 7/25/2017 9:16:00 AM Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Jamie Hotchkiss Export Inspection Report
21 8/5/2016 1:16:01 PM 9/30/2017 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
21 7/22/2015 8:47:01 AM 9/30/2016 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
21 5/4/2015 9:54:01 AM 9/30/2016 12:00:00 AM Spot Checks Approved None Jamie Hotchkiss Export Inspection Report
21 10/22/2014 9:16:50 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
21 7/14/2014 10:32:00 AM Annual Out of Service
  • If required, positive door opening device is missing or fails to operate properly.
Jamie Hotchkiss Export Inspection Report
21 7/16/2013 9:17:01 AM 9/30/2014 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
21 7/11/2012 8:37:00 AM 9/30/2013 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report