NORTHERN WELLS COMM. SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
19 12/4/2023 10:40:01 AM 7/4/2024 10:40:01 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
19 12/4/2023 10:40:00 AM Semi-Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Steve Spallinger Export Inspection Report
19 7/21/2023 9:44:01 AM 2/21/2024 9:44:01 AM Annual Approved None Steve Spallinger Export Inspection Report
19 1/17/2023 9:52:01 AM 8/17/2023 9:52:01 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
19 12/20/2022 9:42:00 AM 1/18/2023 9:42:00 AM Semi-Annual Ordered Repaired
  • The first aid kit is not complete: One (1) package adhesive bandages; containing a total of sixteen (16) 1" x 3" bandages, 1 roll 1”x5yd, 1 blunt scissor, 6 3x3” gauze pads (sterile), 4 2”x5yd gauze stretch material (nonsterile), 3 oval eye pads (sterile), 2 triangular bandages, 1 instruction.
Steve Spallinger Export Inspection Report
19 8/9/2022 9:44:01 AM 3/9/2023 9:44:01 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
19 7/12/2022 10:38:00 AM Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Steve Spallinger Export Inspection Report
19 12/1/2021 9:33:01 AM 7/1/2022 9:33:01 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
19 11/2/2021 11:44:00 AM 12/1/2021 11:44:00 AM Semi-Annual Ordered Repaired
  • See Notes: Any defect inspector deems a violation not listed
Jamie Hotchkiss Export Inspection Report
19 7/23/2021 10:26:01 AM 2/23/2022 10:26:01 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
19 6/4/2021 10:56:00 AM Re-Inspection Out of Service
  • Exhaust leak exceeding one (1) inch measurable in any direction or half (½) inch in diameter.
Jamie Hotchkiss Export Inspection Report
19 6/4/2021 10:54:00 AM Annual Out of Service
  • Exhaust leak exceeding one (1) inch measurable in any direction or half (½) inch in diameter.
  • Any marker light or lens is missing, cracked, faded, wrong color, or inoperative
Jamie Hotchkiss Export Inspection Report
19 5/18/2020 8:59:01 AM 9/30/2021 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
19 7/25/2019 8:35:01 AM 9/30/2020 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
19 7/25/2019 8:27:00 AM 8/23/2019 8:27:00 AM Annual Ordered Repaired
  • Washers do not function properly in any manner
Jamie Hotchkiss Export Inspection Report
19 7/25/2018 9:13:01 AM 9/30/2019 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
19 7/25/2018 8:58:00 AM 8/23/2018 8:58:00 AM Annual Ordered Repaired
  • Required back-up lights do not function.
Jamie Hotchkiss Export Inspection Report
19 7/26/2017 8:20:01 AM 9/30/2018 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
19 7/27/2016 8:10:01 AM 9/30/2017 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
19 7/22/2015 10:30:01 AM 9/30/2016 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
19 7/16/2014 8:16:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
19 7/16/2014 8:15:00 AM 8/14/2014 8:15:00 AM Annual Ordered Repaired
  • The trash container is not securely fastened
Jamie Hotchkiss Export Inspection Report
19 7/16/2013 8:50:01 AM 9/30/2014 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
19 7/11/2012 11:36:00 AM 9/30/2013 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
Go Back New Search