VINCENNES COMM. SCHOOL CORP.
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
18 8/24/2023 9:38:01 AM 9/30/2024 12:00:00 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
18 8/24/2023 9:38:00 AM 9/22/2023 9:38:00 AM Annual Ordered Repaired
  • If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
Bradley MIller Export Inspection Report
18 7/6/2022 9:21:01 AM 9/30/2023 12:00:00 AM Annual Approved None Bradley MIller Export Inspection Report
18 9/15/2021 9:33:01 AM 9/30/2022 12:00:00 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
18 9/15/2021 9:26:00 AM Annual Out of Service
  • Any stop arm light is inoperative
Bradley MIller Export Inspection Report
18 9/14/2020 9:37:01 AM 9/30/2021 12:00:00 AM Annual Approved None Bradley MIller Export Inspection Report
18 8/30/2019 11:21:01 AM 3/30/2020 11:21:01 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
18 8/27/2019 10:37:00 AM 9/25/2019 10:37:00 AM Re-Inspection Ordered Repaired
  • There is movement at any spring loaded drag link or the rod end (using hand pressure)
Bradley MIller Export Inspection Report
18 8/27/2019 9:18:00 AM 9/25/2019 9:18:00 AM Annual Ordered Repaired
  • There is movement at any spring loaded drag link or the rod end (using hand pressure)
  • If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
Bradley MIller Export Inspection Report
18 9/26/2018 1:02:22 PM 4/26/2019 1:02:22 PM Re-Inspection Approved None Bradley MIller Export Inspection Report
18 9/11/2018 8:47:00 AM 10/10/2018 8:47:00 AM Annual Ordered Repaired
  • There is movement at any spring loaded drag link or the rod end (using hand pressure)
Bradley MIller Export Inspection Report
18 9/14/2017 10:51:01 AM 4/14/2018 10:51:01 AM Annual Approved None Bradley MIller Export Inspection Report
18 7/5/2016 9:24:01 AM 9/30/2017 12:00:00 AM Annual Approved None Bradley MIller Export Inspection Report
18 8/24/2015 9:43:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Bradley MIller Export Inspection Report
18 8/24/2015 8:39:00 AM 9/22/2015 8:39:00 AM Annual Ordered Repaired
  • Washers do not function properly in any manner
Bradley MIller Export Inspection Report
18 7/16/2014 9:09:01 AM 9/30/2015 12:00:00 AM Annual Approved None Bradley MIller Export Inspection Report
18 5/15/2013 8:49:01 AM 9/30/2014 12:00:00 AM Annual Approved None Chuck Tharp Export Inspection Report
18 1/25/2013 9:51:01 AM 8/25/2013 9:51:01 AM Semi-Annual Approved None Chuck Tharp Export Inspection Report
18 1/24/2013 11:36:00 AM Semi-Annual Out of Service
  • There is any defect which the inspector feels would adversely affect the ability of the vehicle to stop safely.
  • An exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
  • Emergency window instructions are illegible, missing, or not within 6 inches of the release handle
Chuck Tharp Export Inspection Report
18 1/12/2012 12:26:00 PM 9/30/2013 12:00:00 AM Annual Approved None Roger Cannon Export Inspection Report
18 1/12/2012 12:23:00 PM 9/30/2013 12:00:00 AM Annual Approved None Roger Cannon Export Inspection Report
Go Back New Search