SHENANDOAH SCHOOL CORPORATION
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
35 4/22/2024 11:13:01 AM 11/22/2024 11:13:01 AM Annual Approved None Brandon Steffee Export Inspection Report
35 11/3/2023 9:47:01 AM 6/3/2024 9:47:01 AM Semi-Annual Approved None Jeremy Mason Export Inspection Report
35 4/17/2023 10:37:01 AM 11/17/2023 10:37:01 AM Annual Approved None Jeremy Mason Export Inspection Report
35 10/24/2022 9:37:01 AM 5/24/2023 9:37:01 AM Semi-Annual Approved None Jeremy Mason Export Inspection Report
35 3/31/2022 9:24:01 AM 10/31/2022 9:24:01 AM Annual Approved None Jeremy Mason Export Inspection Report
35 10/25/2021 8:00:01 AM 5/25/2022 8:00:01 AM Semi-Annual Approved None Jeremy Mason Export Inspection Report
35 7/9/2021 1:21:01 PM 2/9/2022 1:21:01 PM Re-Inspection Approved None Jeremy Mason Export Inspection Report
35 5/27/2021 11:03:00 AM 6/25/2021 11:03:00 AM Annual Out of Service
  • Any hanger, clamp or bracket is missing, loose or broken
Jeremy Mason Export Inspection Report
35 11/2/2020 2:57:01 PM 6/2/2021 2:57:01 PM Semi-Annual Approved None Jeremy Mason Export Inspection Report
35 4/6/2020 12:16:01 PM 11/6/2020 12:16:01 PM Annual Approved None Jeremy Mason Export Inspection Report
35 5/8/2019 10:47:01 AM 9/30/2020 12:00:00 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
35 4/16/2019 10:18:00 AM 5/15/2019 10:18:00 AM Annual Ordered Repaired
  • Any hanger, clamp or bracket is missing, loose or broken
Jeremy Mason Export Inspection Report
35 5/15/2018 4:13:01 PM 9/30/2019 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
35 5/5/2017 10:25:01 AM 9/30/2018 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
35 3/24/2016 9:42:01 AM 9/30/2017 12:00:00 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
35 3/24/2016 9:02:00 AM 4/22/2016 9:02:00 AM Annual Ordered Repaired
  • Step-well light is missing or inoperative
Jeremy Mason Export Inspection Report
35 4/23/2015 10:42:01 AM 9/30/2016 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
35 5/8/2014 10:18:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
35 5/8/2014 10:15:00 AM 6/6/2014 10:15:00 AM Annual Ordered Repaired
  • Step-well light is missing or inoperative
Jeremy Mason Export Inspection Report
35 5/30/2013 10:30:01 AM 9/30/2014 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
35 2/7/2013 7:53:01 AM 9/30/2014 12:00:00 AM Post-Crash Inspection Approved None Dave Whitinger Export Inspection Report
35 6/4/2012 10:14:00 AM 9/30/2013 12:00:00 AM Re-Inspection Approved None Dave Whitinger Export Inspection Report
35 6/4/2012 10:14:00 AM Annual Out of Service
  • There are loose or missing bolts or rivets where front and rear spring hangers are attached to the frame.
Dave Whitinger Export Inspection Report
Go Back New Search