SWITZERLAND COUNTY SCHOOL CORP
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
9 5/1/2024 8:49:01 AM 12/1/2024 8:49:01 AM Annual Approved None Chris Clark Export Inspection Report
9 4/13/2023 8:52:01 AM 9/30/2024 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
9 3/28/2022 9:38:01 AM 9/30/2023 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
9 4/21/2021 9:47:01 AM 9/30/2022 12:00:00 AM Annual Approved None Chris Clark Export Inspection Report
9 7/1/2020 9:30:01 AM 9/30/2021 12:00:00 AM Annual Approved None Dan Elmore Export Inspection Report
9 4/8/2019 8:59:01 AM 11/8/2019 8:59:01 AM Re-Inspection Approved None Chris Clark Export Inspection Report
9 4/2/2019 8:29:00 AM 5/1/2019 8:29:00 AM Re-Inspection Ordered Repaired
  • Any dome light is inoperative
Chris Clark Export Inspection Report
9 10/2/2018 9:12:01 AM 5/2/2019 9:12:01 AM Semi-Annual Approved None Chris Clark Export Inspection Report
9 3/23/2018 8:14:01 AM 10/23/2018 8:14:01 AM Re-Inspection Approved None Chris Clark Export Inspection Report
9 3/14/2018 9:34:00 AM Annual Out of Service
  • If the words “EMERGENCY EXIT” does not appear on the top or bottom of the window or directly above each emergency exit window on the inside of the bus
  • There is loose or unprotected wiring in passenger area
Chris Clark Export Inspection Report
9 3/15/2017 10:51:01 AM 9/30/2018 12:00:00 AM Re-Inspection Approved None Chris Clark Export Inspection Report
9 3/15/2017 9:58:00 AM Annual Out of Service
  • If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
  • Any emergency window will not open
Chris Clark Export Inspection Report
9 4/6/2016 10:05:01 AM 9/30/2017 12:00:00 AM Re-Inspection Approved None Chris Clark Export Inspection Report
9 4/6/2016 9:24:00 AM 5/5/2016 9:24:00 AM Annual Ordered Repaired
  • There are unauthorized attachments to the exterior of the bus
Chris Clark Export Inspection Report
9 3/24/2015 8:25:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Chris Clark Export Inspection Report
9 3/23/2015 10:28:00 AM 4/21/2015 10:28:00 AM Annual Ordered Repaired
  • The first aid or bodily fluid (optional) kit is not securely mounted, inside, in a location accessible to the driver in plain view, or if in a bulkhead or storage compartment, is not secured, or the cover of the bulkhead/storage compartment is not clearly labeled "Emergency Equipment."
  • Seatbelts are badly worn, broken or not anchored securely
Chris Clark Export Inspection Report
9 4/7/2014 8:40:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Chris Clark Export Inspection Report
9 3/31/2014 11:29:00 AM 4/29/2014 11:29:00 AM Annual Ordered Repaired
  • The stop arm lights do not flash alternately
Chris Clark Export Inspection Report
9 3/4/2013 10:32:01 AM 9/30/2014 12:00:00 AM Re-Inspection Approved None Chris Clark Export Inspection Report
9 3/4/2013 9:02:00 AM 4/2/2013 9:02:00 AM Annual Ordered Repaired
  • The service door does not open or close properly
  • Door seals are missing, damaged, or torn.
Chris Clark Export Inspection Report
9 5/2/2012 11:45:00 AM 9/30/2013 12:00:00 AM Re-Inspection Approved None Chris Clark Export Inspection Report
9 5/2/2012 10:31:00 AM Annual Out of Service
  • Stop arm does not fully extend to a right angle to the bus
Chris Clark Export Inspection Report
Go Back New Search