SOUTHWEST SULLIVAN SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
29 9/27/2023 9:57:01 AM 4/27/2024 9:57:01 AM Annual Approved None Byron Goodman Export Inspection Report
29 4/26/2023 11:11:01 AM 11/26/2023 11:11:01 AM Semi-Annual Approved None Byron Goodman Export Inspection Report
29 9/15/2022 11:01:01 AM 4/15/2023 11:01:01 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
29 9/15/2022 11:01:00 AM 10/14/2022 11:01:00 AM Re-Inspection Ordered Repaired
  • Required back-up lights do not function.
Byron Goodman Export Inspection Report
29 3/16/2022 9:45:01 AM 10/16/2022 9:45:01 AM Semi-Annual Approved None Byron Goodman Export Inspection Report
29 10/6/2021 10:09:01 AM 5/6/2022 10:09:01 AM Annual Approved None Byron Goodman Export Inspection Report
29 3/29/2021 10:45:01 AM 10/29/2021 10:45:01 AM Semi-Annual Approved None Byron Goodman Export Inspection Report
29 1/15/2021 11:16:01 AM 8/15/2021 11:16:01 AM Semi-Annual Approved None Byron Goodman Export Inspection Report
29 5/19/2020 11:31:01 AM 12/19/2020 11:31:01 AM Semi-Annual Approved None Byron Goodman Export Inspection Report
29 11/20/2019 11:10:01 AM 6/20/2020 11:10:01 AM Re-Inspection Approved None Byron Goodman Export Inspection Report
29 2/8/2019 11:46:01 AM 9/8/2019 11:46:01 AM Semi-Annual Approved None Byron Goodman Export Inspection Report
29 9/17/2018 12:36:01 PM 4/17/2019 12:36:01 PM Annual Approved None Byron Goodman Export Inspection Report
29 2/2/2018 9:55:01 AM 9/2/2018 9:55:01 AM Semi-Annual Approved None Tyler VanNess Export Inspection Report
29 7/11/2017 8:47:01 AM 2/11/2018 8:47:01 AM Annual Approved None Tyler VanNess Export Inspection Report
29 1/6/2017 10:31:01 AM 8/6/2017 10:31:01 AM Re-Inspection Approved None Tyler VanNess Export Inspection Report
29 11/22/2016 9:26:00 AM 12/21/2016 9:26:00 AM Spot Checks Out of Service
  • Not securely mounted
  • Upholstery or padding is ripped, torn, or improperly repaired
Tyler VanNess Export Inspection Report
29 7/20/2016 9:35:01 AM 9/30/2017 12:00:00 AM Re-Inspection Approved None Tyler VanNess Export Inspection Report
29 7/19/2016 8:36:00 AM 8/17/2016 8:36:00 AM Annual Ordered Repaired
  • Air leak at proper connection
Tyler VanNess Export Inspection Report
29 7/20/2015 9:39:01 AM 9/30/2016 12:00:00 AM Annual Approved None Tyler VanNess Export Inspection Report
29 7/21/2014 3:29:01 PM 9/30/2015 12:00:00 AM Annual Approved None Tyler VanNess Export Inspection Report
29 7/22/2013 9:53:01 AM 9/30/2014 12:00:00 AM Re-Inspection Approved None Chuck Tharp Export Inspection Report
29 7/22/2013 8:22:00 AM Annual Out of Service
  • The required low air-pressure warning device fails to operate properly
Chuck Tharp Export Inspection Report
29 7/25/2012 9:03:00 AM 9/30/2013 12:00:00 AM Annual Approved None Chuck Tharp Export Inspection Report
Go Back New Search