SOUTH DEARBORN COMM. SCH. CORP
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
13 4/23/2024 9:06:01 AM 11/23/2024 9:06:01 AM Annual Approved None Chris Clark Export Inspection Report
13 9/12/2023 8:43:01 AM 4/12/2024 8:43:01 AM Semi-Annual Approved None Chris Clark Export Inspection Report
13 4/26/2023 8:08:01 AM 11/26/2023 8:08:01 AM Annual Approved None Chris Clark Export Inspection Report
13 9/12/2017 9:26:01 AM 4/12/2018 9:26:01 AM Semi-Annual Approved None Chris Clark Export Inspection Report
13 2/15/2017 9:32:01 AM 9/15/2017 9:32:01 AM Annual Approved None Chris Clark Export Inspection Report
13 9/26/2016 8:38:01 AM 4/26/2017 8:38:01 AM Semi-Annual Approved None Chris Clark Export Inspection Report
13 2/25/2016 10:49:01 AM 9/25/2016 10:49:01 AM Re-Inspection Approved None Chris Clark Export Inspection Report
13 2/24/2016 8:50:00 AM 3/24/2016 8:50:00 AM Annual Ordered Repaired
  • A heater motor is not operating properly
Chris Clark Export Inspection Report
13 12/29/2015 9:49:01 AM 7/29/2016 9:49:01 AM Semi-Annual Approved None Chris Clark Export Inspection Report
13 2/25/2015 9:26:01 AM 9/25/2015 9:26:01 AM Annual Approved None Chris Clark Export Inspection Report
13 7/21/2014 11:33:01 AM 9/30/2015 12:00:00 AM Registration Approved None Chris Clark Export Inspection Report
13 3/21/2014 9:12:01 AM 10/21/2014 9:12:01 AM Annual Approved None Chris Clark Export Inspection Report
13 9/20/2013 8:42:01 AM 4/20/2014 8:42:01 AM Semi-Annual Approved None Chris Clark Export Inspection Report
13 9/18/2013 9:01:00 AM 10/17/2013 9:01:00 AM Semi-Annual Ordered Repaired
  • The required low air-pressure warning device fails to operate properly
  • Required instrument or gauge is inoperative.
Chris Clark Export Inspection Report
13 2/25/2013 9:55:01 AM 9/25/2013 9:55:01 AM Re-Inspection Approved None Chris Clark Export Inspection Report
13 2/25/2013 9:54:00 AM 3/26/2013 9:54:00 AM Annual Ordered Repaired
  • Required back-up lights do not function.
Chris Clark Export Inspection Report
13 9/28/2012 9:09:00 AM 4/28/2013 9:09:00 AM Semi-Annual Approved None Chris Clark Export Inspection Report
13 4/11/2012 10:10:00 AM 11/11/2012 10:10:00 AM Annual Approved None Chris Clark Export Inspection Report
Go Back New Search