MARION COMMUNITY SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
64 4/12/2024 9:38:01 AM 9/30/2025 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
64 4/12/2024 9:38:00 AM 5/11/2024 9:38:00 AM Annual Ordered Repaired
  • The first aid kit is not complete: One (1) package adhesive bandages; containing a total of sixteen (16) 1" x 3" bandages, 1 roll 1”x5yd, 1 blunt scissor, 6 3x3” gauze pads (sterile), 4 2”x5yd gauze stretch material (nonsterile), 3 oval eye pads (sterile), 2 triangular bandages, 1 instruction.
Randy McPike Export Inspection Report
64 3/10/2023 10:56:01 AM 9/30/2024 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
64 3/10/2023 10:56:00 AM 4/8/2023 10:56:00 AM Annual Ordered Repaired
  • Non safety related signs/decorations posted.
Randy McPike Export Inspection Report
64 4/21/2022 10:57:01 AM 9/30/2023 12:00:00 AM Annual Approved None Randy McPike Export Inspection Report
64 3/12/2021 9:49:01 AM 9/30/2022 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
64 3/12/2021 9:49:00 AM 4/10/2021 9:49:00 AM Annual Ordered Repaired
  • Upholstery or padding is ripped, torn, or improperly repaired
Randy McPike Export Inspection Report
64 3/19/2020 10:17:01 AM 9/30/2021 12:00:00 AM Annual Approved None Randy McPike Export Inspection Report
64 3/12/2019 11:16:01 AM 9/30/2020 12:00:00 AM Annual Approved None Randy McPike Export Inspection Report
64 3/9/2018 8:50:01 AM 9/30/2019 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
64 3/9/2018 8:50:00 AM 4/7/2018 8:50:00 AM Annual Ordered Repaired
  • The first aid kit is not complete: 3 packs of 16 1x3 adhesive strips, 1 scissor (4” min), 2 40”x40”x56” triangular bandages, 6 3”x3” gauze pads, 4 2”x4.1 yard rolls of gauze, 3 oval eye pads, 1 1”x5 yard of adhesive tape, 1 label instruction.
Randy McPike Export Inspection Report
64 3/10/2017 10:26:01 AM 9/30/2018 12:00:00 AM Annual Approved None Randy McPike Export Inspection Report
64 11/15/2016 9:13:01 AM 9/30/2017 12:00:00 AM Registration Approved None Randy McPike Export Inspection Report
64 10/13/2016 8:26:01 AM 5/13/2017 8:26:01 AM Semi-Annual Approved None Randy McPike Export Inspection Report
64 4/7/2016 11:44:01 AM 11/7/2016 11:44:01 AM Annual Approved None Randy McPike Export Inspection Report
64 10/30/2015 10:13:01 AM 5/30/2016 10:13:01 AM Semi-Annual Approved None Randy McPike Export Inspection Report
64 4/9/2015 10:23:01 AM 11/9/2015 10:23:01 AM Annual Approved None Randy McPike Export Inspection Report
64 10/24/2014 8:48:01 AM 5/24/2015 8:48:01 AM Semi-Annual Approved None Randy McPike Export Inspection Report
64 4/22/2014 9:11:01 AM 11/22/2014 9:11:01 AM Annual Approved None Randy McPike Export Inspection Report
64 5/8/2013 9:10:01 AM 9/30/2014 12:00:00 AM Re-Inspection Approved None Randy McPike Export Inspection Report
64 5/8/2013 9:10:00 AM 6/6/2013 9:10:00 AM Annual Ordered Repaired
  • The words "EMERGENCY EXIT" does not appear directly above each emergency exit window on the inside of the bus
Randy McPike Export Inspection Report
64 4/4/2012 10:48:00 AM 9/30/2013 12:00:00 AM Annual Approved None Randy McPike Export Inspection Report