Bus # |
Inspection Date/Time |
Inspection Valid Until |
Inspection Type |
Inspection Status |
Violations |
Inspected By |
Reports |
17 |
4/10/2024 9:24:01 AM |
11/10/2024 9:24:01 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
4/10/2024 9:24:00 AM |
5/9/2024 9:24:00 AM |
Annual |
Ordered Repaired |
- Washers do not function properly in any manner
|
Randy McPike |
|
17 |
9/14/2023 10:54:01 AM |
4/14/2024 10:54:01 AM |
Semi-Annual |
Approved |
None
|
Randy McPike |
|
17 |
4/26/2023 10:08:01 AM |
11/26/2023 10:08:01 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
4/26/2023 10:08:00 AM |
|
Annual |
Out of Service |
- Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
|
Randy McPike |
|
17 |
4/20/2022 9:53:01 AM |
9/30/2023 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
4/20/2022 9:53:00 AM |
|
Annual |
Out of Service |
- If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
- Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
- There are loose items that would create a hazard. (Broom, Scraper, Items on dash etc.)
- The first aid kit is not complete: One (1) package adhesive bandages; containing a total of sixteen (16) 1" x 3" bandages, 1 roll 1”x5yd, 1 blunt scissor, 6 3x3” gauze pads (sterile), 4 2”x5yd gauze stretch material (nonsterile), 3 oval eye pads (sterile), 2 triangular bandages, 1 instruction.
|
Randy McPike |
|
17 |
4/16/2021 9:19:01 AM |
9/30/2022 12:00:00 AM |
Annual |
Approved |
None
|
Randy McPike |
|
17 |
3/20/2020 10:59:01 AM |
9/30/2021 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
3/20/2020 10:20:00 AM |
4/18/2020 10:20:00 AM |
Annual |
Ordered Repaired |
- Any belt is improperly adjusted
|
Randy McPike |
|
17 |
3/11/2019 9:08:01 AM |
9/30/2020 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
3/11/2019 8:52:00 AM |
|
Annual |
Out of Service |
- Any brake line or hose is abraded (chafed), cracked, bulging or leaking (leaking at other than a proper connection).
|
Randy McPike |
|
17 |
3/8/2018 9:23:01 AM |
9/30/2019 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
3/8/2018 9:22:00 AM |
|
Annual |
Out of Service |
- If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
- Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
|
Randy McPike |
|
17 |
4/6/2017 11:02:01 AM |
9/30/2018 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
4/6/2017 11:01:00 AM |
5/5/2017 11:01:00 AM |
Annual |
Ordered Repaired |
- The first aid kit is not complete: 3 packs of 16 1x3 adhesive strips, 1 scissor (4” min), 2 40”x40”x56” triangular bandages, 6 3”x3” gauze pads, 4 2”x4.1 yard rolls of gauze, 3 oval eye pads, 1 1”x5 yard of adhesive tape, 1 label instruction.
|
Randy McPike |
|
17 |
3/14/2016 10:49:01 AM |
9/30/2017 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
3/14/2016 10:49:00 AM |
|
Annual |
Out of Service |
- Led lights have 25% to 49 % of pixels inoperable
- Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
|
Randy McPike |
|
17 |
3/13/2015 8:59:01 AM |
9/30/2016 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Randy McPike |
|
17 |
3/13/2015 8:58:00 AM |
|
Annual |
Out of Service |
- Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
|
Randy McPike |
|
17 |
3/20/2014 8:47:01 AM |
9/30/2015 12:00:00 AM |
Annual |
Approved |
None
|
Randy McPike |
|
17 |
4/4/2013 10:05:01 AM |
9/30/2014 12:00:00 AM |
Annual |
Approved |
None
|
Randy McPike |
|
17 |
4/4/2012 10:58:00 AM |
9/30/2013 12:00:00 AM |
Annual |
Approved |
None
|
Randy McPike |
|