Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
13 2/14/2024 10:15:01 AM 9/14/2024 10:15:01 AM Annual Approved None Troy Boyd Export Inspection Report
13 8/30/2023 8:55:01 AM 3/30/2024 8:55:01 AM Re-Inspection Approved None Troy Boyd Export Inspection Report
13 8/29/2023 10:25:00 AM 9/27/2023 10:25:00 AM Semi-Annual Ordered Repaired
  • Required back-up lights do not function.
Troy Boyd Export Inspection Report
13 2/22/2023 9:08:01 AM 9/22/2023 9:08:01 AM Annual Approved None Troy Boyd Export Inspection Report
13 2/16/2022 8:54:01 AM 9/30/2023 12:00:00 AM Annual Approved None Troy Boyd Export Inspection Report
13 3/11/2020 9:23:01 AM 9/30/2021 12:00:00 AM Annual Approved None Troy Boyd Export Inspection Report
13 2/14/2019 9:43:01 AM 9/30/2020 12:00:00 AM Annual Approved None Troy Boyd Export Inspection Report
13 2/14/2018 8:22:01 AM 9/30/2019 12:00:00 AM Annual Approved None Troy Boyd Export Inspection Report
13 7/18/2017 8:41:01 AM 2/18/2018 8:41:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
13 1/10/2017 8:38:01 AM 8/10/2017 8:38:01 AM Annual Approved None Troy Boyd Export Inspection Report
13 9/20/2016 10:09:01 AM 4/20/2017 10:09:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
13 4/22/2016 9:52:01 AM 11/22/2016 9:52:01 AM Re-Inspection Approved None Troy Boyd Export Inspection Report
13 4/19/2016 8:45:00 AM 5/18/2016 8:45:00 AM Annual Ordered Repaired
  • The bus body has rust or rusted through areas which may weaken the body
Troy Boyd Export Inspection Report
13 8/7/2015 8:32:01 AM 3/7/2016 8:32:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
13 8/7/2015 8:21:00 AM 9/5/2015 8:21:00 AM Semi-Annual Ordered Repaired
  • Any front turn signal does not function properly
Troy Boyd Export Inspection Report
13 1/27/2015 8:18:01 AM 8/27/2015 8:18:01 AM Annual Approved None Troy Boyd Export Inspection Report
13 8/12/2014 8:31:01 AM 3/12/2015 8:31:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
13 8/12/2014 8:16:00 AM 9/10/2014 8:16:00 AM Semi-Annual Ordered Repaired
  • An exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
Troy Boyd Export Inspection Report
13 1/27/2014 10:37:01 AM 8/27/2014 10:37:01 AM Annual Approved None Troy Boyd Export Inspection Report
13 8/2/2013 7:56:01 AM 3/2/2014 7:56:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
13 2/15/2013 8:29:01 AM 9/15/2013 8:29:01 AM Re-Inspection Approved None Troy Boyd Export Inspection Report
13 2/13/2013 10:24:00 AM 3/14/2013 10:24:00 AM Annual Ordered Repaired
  • If required, positive door opening device is missing or fails to operate properly.
Troy Boyd Export Inspection Report
13 8/10/2012 5:15:00 PM 3/10/2013 5:15:00 PM Semi-Annual Approved None Troy Boyd Export Inspection Report
13 7/3/2012 8:49:00 AM Semi-Annual Out of Service
  • Washers do not function properly in any manner
Troy Boyd Export Inspection Report
13 1/4/2012 9:31:00 AM 8/4/2012 9:31:00 AM Re-Inspection Approved None Troy Boyd Export Inspection Report
13 1/4/2012 8:27:00 AM 2/2/2012 8:27:00 AM Annual Ordered Repaired
  • Any clearance light is missing, cracked, faded, wrong color, or inoperative.
Troy Boyd Export Inspection Report
Go Back New Search