CONCORD COMMUNITY SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
15 4/16/2024 9:42:01 AM 9/30/2025 12:00:00 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
15 4/15/2024 10:51:00 AM 5/14/2024 10:51:00 AM Annual Ordered Repaired
  • Air leak at proper connection
Wes Rowlader Export Inspection Report
15 4/10/2023 11:12:01 AM 9/30/2024 12:00:00 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
15 4/10/2023 11:12:00 AM 5/9/2023 11:12:00 AM Annual Ordered Repaired
  • If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
Wes Rowlader Export Inspection Report
15 4/7/2022 12:26:01 PM 9/30/2023 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
15 3/31/2021 11:01:01 AM 9/30/2022 12:00:00 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
15 3/31/2021 11:01:00 AM Annual Out of Service
  • Flip seat does not stay in the upright position when no passengers are seated
Wes Rowlader Export Inspection Report
15 7/15/2020 11:08:01 AM 9/30/2021 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
15 4/8/2019 10:39:01 AM 9/30/2020 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
15 10/11/2017 11:20:01 AM 5/11/2018 11:20:01 AM Semi-Annual Approved None Wes Rowlader Export Inspection Report
15 4/12/2017 10:07:01 AM 11/12/2017 10:07:01 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
15 4/12/2017 9:44:00 AM Re-Inspection Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Wes Rowlader Export Inspection Report
15 4/12/2017 9:42:00 AM Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
  • One (1) taillight or one (1) brake light does not function
Wes Rowlader Export Inspection Report
15 4/19/2016 8:52:01 AM 9/30/2017 12:00:00 AM Re-Inspection Approved None Brian Bills Export Inspection Report
15 4/14/2016 10:29:00 AM 5/13/2016 10:29:00 AM Annual Ordered Repaired
  • A dripping oil or fluid leak
Brian Bills Export Inspection Report
15 4/16/2015 9:50:01 AM 9/30/2016 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
15 4/16/2015 9:50:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Brian Bills Export Inspection Report
15 4/16/2014 11:42:01 AM 9/30/2015 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
15 4/12/2013 11:38:01 AM 9/30/2014 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
15 10/8/2012 1:17:00 PM 9/30/2013 12:00:00 AM Annual Approved None Travis Harrold Export Inspection Report
Go Back New Search