SCOTT COUNTY SCHOOL DISTRICT 2
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
7 9/25/2026 9:01:01 AM 4/25/2027 9:01:01 AM Re-Inspection Approved None Mike Martin Export Inspection Report
7 9/25/2026 8:44:00 AM 10/24/2026 8:44:00 AM Re-Inspection Ordered Repaired
  • A heater motor is not operating properly
Mike Martin Export Inspection Report
7 9/2/2026 8:17:00 AM Semi-Annual Out of Service
  • There is body damage which could cause injury to persons near the bus (e.g. jagged metal edges, etc.)((Exigent circumstance can be taken into consideration to allow the bus to return home in a post crash inspection if bus is out of its district)).
  • A heater motor is not operating properly
Mike Martin Export Inspection Report
7 3/9/2026 8:00:01 AM 10/9/2026 8:00:01 AM Re-Inspection Approved None Mike Martin Export Inspection Report
7 2/10/2026 10:54:00 AM 3/11/2026 10:54:00 AM Annual Ordered Repaired
  • A heater motor is not operating properly
Troy Boyd Export Inspection Report
7 9/3/2025 9:28:01 AM 4/3/2026 9:28:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
7 1/30/2025 8:34:01 AM 8/30/2025 8:34:01 AM Annual Approved None Troy Boyd Export Inspection Report
7 8/22/2024 8:46:01 AM 3/22/2025 8:46:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
7 2/9/2024 8:57:01 AM 9/9/2024 8:57:01 AM Annual Approved None Troy Boyd Export Inspection Report
7 8/25/2023 10:07:01 AM 3/25/2024 10:07:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
7 2/15/2023 12:48:01 PM 9/15/2023 12:48:01 PM Re-Inspection Approved None Troy Boyd Export Inspection Report
7 2/15/2023 9:48:00 AM 3/16/2023 9:48:00 AM Annual Ordered Repaired
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
Troy Boyd Export Inspection Report
7 8/31/2022 10:19:01 AM 3/31/2023 10:19:01 AM Re-Inspection Approved None Troy Boyd Export Inspection Report
7 8/31/2022 8:33:00 AM Semi-Annual Out of Service
  • Any dome light is inoperative
  • Is no audible signal when the emergency door is open and ignition switch is on
Troy Boyd Export Inspection Report
7 2/9/2022 9:34:01 AM 9/9/2022 9:34:01 AM Annual Approved None Troy Boyd Export Inspection Report
7 7/21/2021 8:38:01 AM 2/21/2022 8:38:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
7 2/9/2021 10:07:01 AM 9/9/2021 10:07:01 AM Annual Approved None Troy Boyd Export Inspection Report
7 8/20/2020 10:01:01 AM 3/20/2021 10:01:01 AM Semi-Annual Approved None Troy Boyd Export Inspection Report
7 2/18/2020 9:10:01 AM 9/18/2020 9:10:01 AM Annual Approved None Troy Boyd Export Inspection Report
7 4/8/2019 11:59:32 AM 9/30/2020 12:00:00 AM Annual Approved None Troy Boyd Export Inspection Report
Go Back New Search