| Bus # |
Inspection Date/Time |
Inspection Valid Until |
Inspection Type |
Inspection Status |
Violations |
Inspected By |
Reports |
| 403 |
8/10/2026 8:30:01 AM |
9/30/2027 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Nathan Sherer |
|
| 403 |
7/23/2026 11:40:00 AM |
8/21/2026 11:40:00 AM |
Annual |
Ordered Repaired |
- If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
|
TOM DEVRIES |
|
| 403 |
8/6/2025 9:48:01 AM |
9/30/2026 12:00:00 AM |
Annual |
Approved |
None
|
Nathan Sherer |
|
| 403 |
8/8/2024 8:26:01 AM |
9/30/2025 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Nathan Sherer |
|
| 403 |
7/31/2024 8:48:00 AM |
8/29/2024 8:48:00 AM |
Annual |
Ordered Repaired |
- Step-well light is missing or inoperative
- Upholstery or padding is ripped, torn, or improperly repaired
- Any battery is loose in its mounting.
- Air leak at proper connection
|
Nathan Sherer |
|
| 403 |
9/20/2023 9:38:01 AM |
9/30/2024 12:00:00 AM |
Re-Inspection |
Approved |
None
|
Nathan Sherer |
|
| 403 |
8/14/2023 10:17:00 AM |
9/12/2023 10:17:00 AM |
Annual |
Out of Service |
- Reservoir is empty
- LED type lights have 25% to 49% pixels inoperable in any one light. (NOTE: one letter in the word “STOP” equals one light
- The seat belt cutter is not secured using a positive fastening method.
|
Nathan Sherer |
|