NORTHERN WELLS COMM. SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
40 7/29/2024 11:47:01 AM 9/30/2025 12:00:00 AM Annual Approved None Steve Spallinger Export Inspection Report
40 7/25/2023 11:30:01 AM 9/30/2024 12:00:00 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
40 7/25/2023 11:10:00 AM Re-Inspection Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Steve Spallinger Export Inspection Report
40 7/25/2023 11:08:00 AM Annual Out of Service
  • Excessive effort is needed to open the emergency door
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Steve Spallinger Export Inspection Report
40 8/9/2022 8:56:01 AM 9/30/2023 12:00:00 AM Re-Inspection Approved None Steve Spallinger Export Inspection Report
40 7/14/2022 9:10:00 AM 8/12/2022 9:10:00 AM Annual Ordered Repaired
  • Any component has deteriorated and allows the escape of exhaust gases (with the engine idling and the system unrestricted)
Steve Spallinger Export Inspection Report
40 6/3/2021 8:30:01 AM 9/30/2022 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
40 6/10/2020 8:44:01 AM 9/30/2021 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
40 7/18/2019 2:48:01 PM 9/30/2020 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
40 7/18/2019 2:47:00 PM Annual Out of Service
  • There is no brake certification, or the certification has expired or is not signed
Jamie Hotchkiss Export Inspection Report
40 7/25/2018 10:05:01 AM 9/30/2019 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
40 8/17/2017 12:36:54 PM 9/30/2018 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
40 7/26/2017 10:24:00 AM 8/24/2017 10:24:00 AM Annual Ordered Repaired
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
  • Any dome light is inoperative
Jamie Hotchkiss Export Inspection Report
40 7/27/2016 9:43:01 AM 9/30/2017 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
40 7/21/2015 10:24:01 AM 9/30/2016 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
40 7/16/2014 9:47:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
40 7/16/2014 9:33:00 AM Annual Out of Service
  • There is no brake certification, the certification has expired, or is not signed within the six month requirement.
Jamie Hotchkiss Export Inspection Report
40 5/1/2013 10:56:25 AM 9/30/2014 12:00:00 AM Registration Approved None Jamie Hotchkiss Export Inspection Report
40 1/8/2013 10:15:01 AM 8/8/2013 10:15:01 AM Semi-Annual Approved None Jamie Hotchkiss Export Inspection Report
40 12/4/2012 12:02:00 PM Semi-Annual Out of Service
  • The first aid kit is not properly filled in accordance with the '24 Unit Kit'.
Brian Bills Export Inspection Report
40 7/11/2012 11:07:00 AM 2/11/2013 11:07:00 AM Annual Approved None Brian Bills Export Inspection Report
Go Back New Search