NORTHERN WELLS COMM. SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
36 7/21/2023 11:06:01 AM 9/30/2024 12:00:00 AM Annual Approved None Steve Spallinger Export Inspection Report
36 7/14/2022 9:45:01 AM 9/30/2023 12:00:00 AM Annual Approved None Steve Spallinger Export Inspection Report
36 6/3/2021 10:16:01 AM 9/30/2022 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
36 6/10/2020 9:27:01 AM 9/30/2021 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
36 11/18/2019 11:28:01 AM 9/30/2020 12:00:00 AM Re-Inspection Approved None Jamie Hotchkiss Export Inspection Report
36 10/9/2019 12:48:00 PM Post-Crash Inspection Out of Service
  • The trash container is greater than a fourteen (14) quart capacity
  • The trash container is not secured to prevent movement and does not allow for easy removal and replacement
  • There is body damage which could cause injury to persons near the bus (e.g. jagged metal edges, etc.)((Exigent circumstance can be taken into consideration to allow the bus to return home in a post crash inspection if bus is out of its district)).
  • The bus body has loose, damaged or improperly aligned body parts. These would include rivets, bolts, and body panels and/or rub rails
Jamie Hotchkiss Export Inspection Report
36 7/24/2019 9:07:01 AM 9/30/2020 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
36 7/24/2018 10:00:01 AM 9/30/2019 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
36 7/25/2017 10:30:01 AM 9/30/2018 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
36 7/26/2016 9:00:01 AM 9/30/2017 12:00:00 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
36 6/26/2015 10:53:01 AM 9/30/2016 12:00:00 AM Registration Approved None Jamie Hotchkiss Export Inspection Report
36 11/21/2013 10:46:00 AM Semi-Annual Out of Service
  • An exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
  • Exhaust leak occurs in the exhaust system exceeding 1" measurable in any direction or 1/2" in diameter.
  • There is body damage which could cause injury to persons near the bus (i.e. jagged metal edges, etc.).
Jamie Hotchkiss Export Inspection Report
36 7/15/2013 9:17:01 AM 2/15/2014 9:17:01 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
36 7/30/2012 10:29:00 AM 9/30/2013 12:00:00 AM Re-Inspection Approved None Brian Bills Export Inspection Report
36 7/11/2012 12:23:00 PM Annual Out of Service
  • There is body damage which could cause injury to persons near the bus (i.e. jagged metal edges, etc.).
  • Any body surface protrudes beyond the normal limits of the body structure.
  • It shall be mounted, filled and vented outside of the body
  • There is a significant fluid leak from the transmission.
Brian Bills Export Inspection Report
Go Back New Search