26 5/9/2024 8:06:01 AM 9/30/2025 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
26 4/27/2023 2:19:34 PM 9/30/2024 12:00:00 AM Re-Inspection Approved None Nathan Sherer Export Inspection Report
26 4/27/2023 10:10:00 AM 5/26/2023 10:10:00 AM Re-Inspection Ordered Repaired
  • If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
Nathan Sherer Export Inspection Report
26 4/27/2023 9:52:00 AM 5/26/2023 9:52:00 AM Annual Ordered Repaired
  • If the emergency window instructions are illegible or missing. Must be within 6 inches of the release handle
Nathan Sherer Export Inspection Report
26 5/9/2022 10:02:01 AM 9/30/2023 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
26 5/6/2021 9:55:01 AM 9/30/2022 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
26 5/8/2020 9:57:01 AM 9/30/2021 12:00:00 AM Annual Approved None Tim Grayson Export Inspection Report
26 5/2/2019 7:35:01 AM 9/30/2020 12:00:00 AM Annual Approved None Tim Grayson Export Inspection Report
26 5/9/2018 10:06:01 AM 9/30/2019 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
26 5/12/2017 8:04:01 AM 9/30/2018 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
26 8/18/2016 12:21:04 PM 9/30/2017 12:00:00 AM Registration Approved None Nathan Sherer Export Inspection Report
26 5/11/2015 12:17:32 PM 9/30/2016 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
26 3/21/2014 9:43:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Nathan Sherer Export Inspection Report
26 3/19/2014 12:22:00 PM Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
  • Any hanger, clamp or bracket is missing, loose or broken.
  • Any component has deteriorated and allows the escape of exhaust gases (with the engine idling and the system unrestricted).
  • There is no audible signal when the emergency door is open and ignition switch is on.
  • If equipped, the emergency warning buzzer does not sound.
Nathan Sherer Export Inspection Report
26 5/22/2013 12:23:01 PM 9/30/2014 12:00:00 AM Re-Inspection Approved None Nathan Sherer Export Inspection Report
26 5/13/2013 3:43:00 PM Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
  • There is movement in a spring loaded drag link greater than 1/8 inch
  • An exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
Nathan Sherer Export Inspection Report
26 5/2/2012 1:49:00 PM 9/30/2013 12:00:00 AM Re-Inspection Approved None David Eggers Export Inspection Report
26 4/16/2012 9:55:00 AM 5/15/2012 9:55:00 AM Re-Inspection Ordered Repaired
  • Exhaust leak occurs in the exhaust system prior to the muffler outlet.
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
David Eggers Export Inspection Report
26 4/16/2012 9:04:00 AM Annual Out of Service
  • A heater motor is inoperative at any speed.
  • Exhaust leak occurs in the exhaust system prior to the muffler outlet.
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
David Eggers Export Inspection Report
Go Back New Search