CENTERVILLE-ABINGTON COMM SCHS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
20 3/21/2024 8:38:01 AM 9/30/2025 12:00:00 AM Annual Approved None Brandon Steffee Export Inspection Report
20 4/11/2023 9:43:01 AM 9/30/2024 12:00:00 AM Registration Approved None Jeremy Mason Export Inspection Report
20 4/10/2023 11:27:01 PM 9/30/2024 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
20 12/2/2022 5:11:01 PM 7/2/2023 5:11:01 PM Semi-Annual Approved None Jeremy Mason Export Inspection Report
20 8/1/2022 5:15:01 PM 3/1/2023 5:15:01 PM Re-Inspection Approved None Jeremy Mason Export Inspection Report
20 7/12/2022 9:26:00 AM 8/10/2022 9:26:00 AM Annual Ordered Repaired
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
Jeremy Mason Export Inspection Report
20 11/29/2021 2:50:53 PM 6/29/2022 2:50:53 PM Semi-Annual Approved None Jeremy Mason Export Inspection Report
20 5/3/2021 4:26:01 PM 12/3/2021 4:26:01 PM Annual Approved None Jeremy Mason Export Inspection Report
20 11/2/2020 12:11:01 PM 6/2/2021 12:11:01 PM Semi-Annual Approved None Jeremy Mason Export Inspection Report
20 7/9/2020 11:11:01 AM 2/9/2021 11:11:01 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
20 4/3/2020 8:38:00 PM 5/2/2020 8:38:00 PM Annual Out of Service
  • Air leak at proper connection
  • Any hanger, clamp or bracket is missing, loose or broken
Jeremy Mason Export Inspection Report
20 5/17/2019 10:52:01 AM 9/30/2020 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
20 5/16/2018 2:18:01 PM 9/30/2019 12:00:00 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
20 5/14/2018 8:42:01 AM 9/30/2019 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
20 3/24/2017 12:43:01 PM 9/30/2018 12:00:00 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
20 3/24/2017 11:34:00 AM 4/22/2017 11:34:00 AM Annual Ordered Repaired
  • The first aid kit is not complete: 3 packs of 16 1x3 adhesive strips, 1 scissor (4” min), 2 40”x40”x56” triangular bandages, 6 3”x3” gauze pads, 4 2”x4.1 yard rolls of gauze, 3 oval eye pads, 1 1”x5 yard of adhesive tape, 1 label instruction.
Jeremy Mason Export Inspection Report
20 5/23/2016 12:38:01 PM 9/30/2017 12:00:00 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
20 4/18/2016 1:05:00 PM Annual Out of Service
  • There is debris in the bus. (needs cleaned/includes dirt)
Jeremy Mason Export Inspection Report
20 4/16/2015 10:13:01 AM 9/30/2016 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
20 4/3/2014 10:19:01 AM 9/30/2015 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
20 3/4/2013 2:47:01 PM 9/30/2014 12:00:00 AM Annual Approved None Dave Whitinger Export Inspection Report
20 3/5/2012 7:05:00 PM 9/30/2013 12:00:00 AM Annual Approved None Dave Whitinger Export Inspection Report
Go Back New Search