WASHINGTON CATHOLIC SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
1B 8/19/2025 10:20:00 AM 9/17/2025 10:20:00 AM Semi-Annual Out of Service
  • Any clearance light is missing, cracked, faded, wrong color, or inoperative
  • Required warning devices are not present
  • The mirrors do not meet the outside mirror standard as set forth in 575 IAC 1-2-49
Philip Lubbers Export Inspection Report
1B 2/28/2025 7:56:01 AM 9/30/2025 7:56:01 AM Re-Inspection Approved None Philip Lubbers Export Inspection Report
1B 1/29/2025 9:58:00 AM 2/27/2025 9:58:00 AM Annual Ordered Repaired
  • There are any breaks, nicks or chips larger than 3/4 inch in diameter in the area covered by the wipers on the drivers’ side
  • Any exhaust leak can be felt with the bare hand six (6) inches from the leak in any direction (with the engine idling and the system unrestricted).
  • Any component has deteriorated and allows the escape of exhaust gases (with the engine idling and the system unrestricted)
Philip Lubbers Export Inspection Report
1B 8/20/2024 9:44:01 AM 3/20/2025 9:44:01 AM Re-Inspection Approved None Philip Lubbers Export Inspection Report
1B 8/20/2024 8:58:00 AM Semi-Annual Out of Service
  • Any stop arm light is inoperative
  • There are any decals or stickers, except those required by law, in the windshield or in the windows to the immediate right or left of the driver
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Philip Lubbers Export Inspection Report
1B 1/9/2024 10:26:01 AM 8/9/2024 10:26:01 AM Re-Inspection Approved None Philip Lubbers Export Inspection Report
1B 1/9/2024 10:16:00 AM 2/7/2024 10:16:00 AM Annual Ordered Repaired
  • A heater motor is not operating properly
Philip Lubbers Export Inspection Report
1B 7/27/2023 11:14:48 AM 2/27/2024 11:14:48 AM Registration Approved None Philip Lubbers Export Inspection Report
1B 8/9/2012 3:41:00 PM 3/9/2013 3:41:00 PM Re-Inspection Approved None Kelly Hammond Export Inspection Report
1B 6/22/2012 11:16:00 AM 1/22/2013 11:16:00 AM Annual Approved None Kelly Hammond Export Inspection Report
Go Back New Search