SOUTH NEWTON SCHOOL CORP.
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
17 6/4/2024 9:29:01 AM 9/30/2025 12:00:00 AM Re-Inspection Approved None Nathan Sherer Export Inspection Report
17 6/4/2024 7:54:00 AM Annual Out of Service
  • Non safety related signs/decorations posted.
  • There is no brake certification, or the certification has expired or is not signed
Nathan Sherer Export Inspection Report
17 6/5/2023 8:56:01 AM 9/30/2024 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
17 6/6/2022 8:16:01 AM 9/30/2023 12:00:00 AM Annual Approved None Tim Grayson Export Inspection Report
17 6/7/2021 8:44:01 AM 9/30/2022 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
17 8/4/2020 8:44:01 AM 9/30/2021 12:00:00 AM Registration Approved None Nathan Sherer Export Inspection Report
17 7/31/2019 9:30:01 AM 9/30/2020 12:00:00 AM Re-Inspection Approved None Tim Grayson Export Inspection Report
17 6/3/2019 9:22:00 AM Annual Out of Service
  • Any hanger, clamp or bracket is missing, loose or broken
  • Any stop arm light is inoperative
Nathan Sherer Export Inspection Report
17 6/1/2018 9:22:01 AM 9/30/2019 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
17 6/7/2017 9:15:01 AM 9/30/2018 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
17 6/3/2016 10:02:01 AM 9/30/2017 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
17 6/5/2015 11:53:01 AM 9/30/2016 12:00:00 AM Re-Inspection Approved None Dale Morgan Export Inspection Report
17 6/5/2015 9:19:00 AM 7/4/2015 9:19:00 AM Annual Ordered Repaired
  • Any hanger, clamp or bracket is missing, loose or broken
  • If equipped the emergency warning buzzer does not sound
  • LED type lights have 25% to 49% pixels inoperable in any one light. (NOTE: one letter in the word "STOP" equals one light
Dale Morgan Export Inspection Report
17 5/9/2014 10:40:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None David Eggers Export Inspection Report
17 5/9/2014 9:15:00 AM Annual Out of Service
  • If equipped, the emergency warning buzzer does not sound.
  • Warning lights fail to operate correctly
David Eggers Export Inspection Report
17 5/2/2013 11:03:01 AM 9/30/2014 12:00:00 AM Re-Inspection Approved None Nathan Sherer Export Inspection Report
17 5/2/2013 11:02:00 AM 5/31/2013 11:02:00 AM Annual Ordered Repaired
  • The first aid kit is not properly filled.
Nathan Sherer Export Inspection Report
17 5/18/2012 9:46:00 AM 9/30/2013 12:00:00 AM Annual Approved None Nathan Sherer Export Inspection Report
Go Back New Search