CENTERVILLE-ABINGTON COMM SCHS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
17 3/21/2024 9:44:01 AM 9/30/2025 12:00:00 AM Annual Approved None Brandon Steffee Export Inspection Report
17 5/8/2023 10:52:01 AM 9/30/2024 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
17 7/12/2022 10:28:01 AM 9/30/2023 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
17 6/21/2021 3:18:01 PM 9/30/2022 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
17 7/17/2020 9:49:01 AM 9/30/2021 12:00:00 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
17 7/9/2020 9:34:00 AM Annual Out of Service
  • Warning lights fail to operate correctly
  • Any brake line or hose is abraded (chafed), cracked, bulging or leaking (leaking at other than a proper connection).
Jeremy Mason Export Inspection Report
17 7/9/2020 9:34:00 AM Annual Out of Service
  • Warning lights fail to operate correctly
  • Any brake line or hose is abraded (chafed), cracked, bulging or leaking (leaking at other than a proper connection).
Jeremy Mason Export Inspection Report
17 4/11/2019 11:01:01 AM 9/30/2020 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
17 6/1/2018 4:29:01 PM 9/30/2019 12:00:00 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
17 5/16/2018 2:10:00 PM 6/14/2018 2:10:00 PM Annual Ordered Repaired
  • The first aid or bodily fluid (optional) kit is not in a dustproof, detachable container, has sharp protrusions, or requires tools to open.
Jeremy Mason Export Inspection Report
17 3/10/2017 11:04:01 AM 9/30/2018 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
17 8/8/2016 12:01:01 PM 9/30/2017 12:00:00 AM Annual Approved None Jeremy Mason Export Inspection Report
17 4/18/2016 10:35:01 AM 11/18/2016 10:35:01 AM Annual Approved None Jeremy Mason Export Inspection Report
17 10/20/2015 7:43:01 AM 5/20/2016 7:43:01 AM Semi-Annual Approved None Jeremy Mason Export Inspection Report
17 10/20/2015 7:43:01 AM 5/20/2016 7:43:01 AM Semi-Annual Approved None Jeremy Mason Export Inspection Report
17 4/16/2015 9:17:01 AM 11/16/2015 9:17:01 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
17 4/2/2015 9:53:00 AM Annual Out of Service
  • Any shock absorber is leaking fluid
  • There is any defect not in compliance with the minimum school bus brake inspection standards
Jeremy Mason Export Inspection Report
17 8/28/2014 12:05:01 PM 3/28/2015 12:05:01 PM Semi-Annual Approved None Jeremy Mason Export Inspection Report
17 3/6/2014 11:40:01 AM 10/6/2014 11:40:01 AM Re-Inspection Approved None Jeremy Mason Export Inspection Report
17 3/6/2014 11:40:00 AM 4/4/2014 11:40:00 AM Annual Ordered Repaired
  • Upholstery or padding is ripped, torn, or improperly repaired.
  • Step-well light is missing or inoperative
Jeremy Mason Export Inspection Report
17 10/15/2013 10:51:01 AM 5/15/2014 10:51:01 AM Semi-Annual Approved None Jeremy Mason Export Inspection Report
17 10/15/2013 10:50:00 AM Semi-Annual Out of Service
  • The required low air-pressure warning device fails to operate properly
Jeremy Mason Export Inspection Report
17 5/15/2013 10:37:01 AM 12/15/2013 10:37:01 AM Annual Approved None Eric Thumb Export Inspection Report
17 11/9/2012 9:19:00 AM 6/9/2013 9:19:00 AM Semi-Annual Approved None Dave Whitinger Export Inspection Report
17 5/15/2012 10:41:00 AM 12/15/2012 10:41:00 AM Re-Inspection Approved None Dave Whitinger Export Inspection Report
17 5/15/2012 10:40:00 AM Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Dave Whitinger Export Inspection Report
Go Back New Search