SOUTH MONTGOMERY COMM SCH CORP
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
15 4/25/2025 11:10:01 AM 9/30/2026 12:00:00 AM Annual Approved None Jared McQueary Export Inspection Report
15 8/28/2024 10:03:01 AM 9/30/2025 12:00:00 AM Registration Approved None Nate King Export Inspection Report
15 12/7/2022 9:55:01 AM 7/7/2023 9:55:01 AM Semi-Annual Approved None Nate King Export Inspection Report
15 5/10/2022 9:30:01 AM 12/10/2022 9:30:01 AM Re-Inspection Approved None Nate King Export Inspection Report
15 4/19/2022 10:48:00 AM Annual Out of Service
  • Exhaust leak exceeding one (1) inch measurable in any direction or half (½) inch in diameter.
  • Any hanger, clamp or bracket is missing, loose or broken
Nate King Export Inspection Report
15 12/9/2021 9:37:01 AM 7/9/2022 9:37:01 AM Semi-Annual Approved None Nate King Export Inspection Report
15 4/28/2021 9:57:01 AM 11/28/2021 9:57:01 AM Annual Approved None Nate King Export Inspection Report
15 11/16/2020 9:19:01 AM 6/16/2021 9:19:01 AM Re-Inspection Approved None Nate King Export Inspection Report
15 11/2/2020 10:40:00 AM Semi-Annual Out of Service
  • Center/carrier bearing: any broken or loose center/carrier bearing bracket, bolts or mounting hardware, any center bearing bracket crack equaling fifty (50) percent or more of the original width, more than one half (1/2) inch vertical movement of the shaft in the center bearing carrier (rubber)
Nate King Export Inspection Report
15 7/28/2020 10:41:01 AM 2/28/2021 10:41:01 AM Re-Inspection Approved None Nate King Export Inspection Report
15 3/31/2020 11:43:00 AM Annual Out of Service
  • Any push-rod travel measures 1/4 inch or more beyond the readjustment limit, or if any two (2) brakes measure less than 1/4 inch beyond the readjustment limit
Nate King Export Inspection Report
15 11/27/2019 8:42:01 AM 6/27/2020 8:42:01 AM Re-Inspection Approved None Nate King Export Inspection Report
15 11/26/2019 9:55:00 AM Semi-Annual Out of Service
  • Any hanger, clamp or bracket is missing, loose or broken
  • Center/carrier bearing: any broken or loose center/carrier bearing bracket, bolts or mounting hardware, any center bearing bracket crack equaling fifty (50) percent or more of the original width, more than one half (1/2) inch vertical movement of the shaft in the center bearing carrier (rubber)
Nate King Export Inspection Report
15 5/22/2019 10:28:01 AM 12/22/2019 10:28:01 AM Annual Approved None Nate King Export Inspection Report
15 1/30/2018 11:03:01 AM 9/30/2019 12:00:00 AM Annual Approved None Nate King Export Inspection Report
15 4/19/2017 10:29:01 AM 9/30/2018 12:00:00 AM Re-Inspection Approved None Nate King Export Inspection Report
15 4/17/2017 10:30:00 AM Annual Out of Service
  • Center/carrier bearing: any broken or loose center/carrier bearing bracket, bolts or mounting hardware, any center bearing bracket crack equaling fifty (50) percent or more of the original width, more than one half (1/2) inch vertical movement of the shaft in the center bearing carrier (rubber)
  • The mirrors do not meet the outside mirror standard as set forth in 575 IAC 1-2-49
Nate King Export Inspection Report
15 5/16/2016 12:52:01 PM 9/30/2017 12:00:00 AM Re-Inspection Approved None Nate King Export Inspection Report
15 4/29/2016 12:30:00 PM 5/28/2016 12:30:00 PM Annual Ordered Repaired
  • There are any loose, broken, or missing mountings
Nate King Export Inspection Report
15 7/31/2015 11:38:01 AM 9/30/2016 12:00:00 AM Registration Approved None Nate King Export Inspection Report
15 8/8/2014 11:05:01 AM 9/30/2015 12:00:00 AM Annual Approved None Nate King Export Inspection Report
15 4/16/2013 9:41:01 AM 9/30/2014 12:00:00 AM Annual Approved None Nate King Export Inspection Report
15 2/21/2012 9:38:00 AM 9/30/2013 12:00:00 AM Re-Inspection Approved None Joel Flores Export Inspection Report
15 2/21/2012 9:38:00 AM Annual Out of Service
  • The first aid kit is not properly filled in accordance with the '24 Unit Kit'.
Joel Flores Export Inspection Report
Go Back New Search