ELKHART COMMUNITY SCHOOLS
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
144 12/14/2023 10:26:01 AM 7/14/2024 10:26:01 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
144 12/14/2023 10:26:00 AM Semi-Annual Out of Service
  • Audible warning device, when required, is not working properly. Buzzers are required after 5-2-94
Wes Rowlader Export Inspection Report
144 6/8/2023 11:49:01 AM 1/8/2024 11:49:01 AM Annual Approved None Wes Rowlader Export Inspection Report
144 10/6/2022 11:38:01 AM 5/6/2023 11:38:01 AM Re-Inspection Approved None Joseph Hartman Export Inspection Report
144 10/6/2022 11:38:00 AM Semi-Annual Out of Service
  • The first aid kit is not complete: One (1) package adhesive bandages; containing a total of sixteen (16) 1" x 3" bandages, 1 roll 1”x5yd, 1 blunt scissor, 6 3x3” gauze pads (sterile), 4 2”x5yd gauze stretch material (nonsterile), 3 oval eye pads (sterile), 2 triangular bandages, 1 instruction.
  • There is no seat belt cutter in the vehicle
Joseph Hartman Export Inspection Report
144 5/16/2022 9:49:01 AM 12/16/2022 9:49:01 AM Annual Approved None Jamie Hotchkiss Export Inspection Report
144 11/4/2021 11:46:01 AM 6/4/2022 11:46:01 AM Semi-Annual Approved None Wes Rowlader Export Inspection Report
144 5/18/2021 10:26:01 AM 12/18/2021 10:26:01 AM Annual Approved None Wes Rowlader Export Inspection Report
144 11/19/2020 9:33:01 AM 6/19/2021 9:33:01 AM Semi-Annual Approved None Wes Rowlader Export Inspection Report
144 5/8/2020 8:27:01 AM 12/8/2020 8:27:01 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
144 5/7/2020 9:27:00 AM Annual Out of Service
  • Switch does not simultaneously disable interior noise-producing accessories such as radios or speakers, NOT including 2 way radios, defroster fans, passenger heater fans, powered roof ventilators, or any other noise- producing device. EXEMPTION Type A buses - OEM accessories not including two-way, AM/FM, Satellite, or similiar.
  • Two (2) or more taillights or brake lights do not function (LED lights are considered non-functional if 50% or more pixels are inoperable in one light.)
Wes Rowlader Export Inspection Report
144 10/10/2019 11:24:01 AM 5/10/2020 11:24:01 AM Semi-Annual Approved None Wes Rowlader Export Inspection Report
144 5/9/2019 12:07:01 PM 12/9/2019 12:07:01 PM Re-Inspection Approved None Wes Rowlader Export Inspection Report
144 5/9/2019 10:29:00 AM 6/7/2019 10:29:00 AM Annual Ordered Repaired
  • Air leak at proper connection
Wes Rowlader Export Inspection Report
144 11/15/2018 10:48:01 AM 6/15/2019 10:48:01 AM Re-Inspection Approved None Wes Rowlader Export Inspection Report
144 11/15/2018 10:48:00 AM 12/14/2018 10:48:00 AM Semi-Annual Ordered Repaired
  • Not fully charged
  • If bus manufactured after 5-2-1994, positive door opening device is missing or fails to operate properly
Wes Rowlader Export Inspection Report
144 6/12/2018 12:04:01 PM 1/12/2019 12:04:01 PM Annual Approved None Wes Rowlader Export Inspection Report
144 5/18/2017 9:43:01 AM 9/30/2018 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
144 6/29/2016 10:50:01 AM 9/30/2017 12:00:00 AM Annual Approved None Wes Rowlader Export Inspection Report
144 6/25/2015 9:10:01 AM 9/30/2016 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
144 7/21/2014 1:01:01 PM 9/30/2015 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
144 5/21/2013 11:16:01 AM 9/30/2014 12:00:00 AM Annual Approved None Brian Bills Export Inspection Report
144 6/11/2012 11:14:00 AM 9/30/2013 12:00:00 AM Annual Approved None Travis Harrold Export Inspection Report
144 6/11/2012 11:14:00 AM 9/30/2013 12:00:00 AM Re-Inspection Approved None Travis Harrold Export Inspection Report
Go Back New Search