M.S.D. DECATUR TOWNSHIP
To view the full report for a bus inspection, click on the PDF icon on the right.

Go Back New Search

Bus Inspections

Bus # Inspection Date/Time Inspection Valid Until Inspection Type Inspection Status Violations Inspected By Reports
10 2/20/2024 9:51:01 AM 9/30/2025 12:00:00 AM Annual Approved None Jeff Stone Export Inspection Report
10 2/15/2023 10:08:01 AM 9/30/2024 12:00:00 AM Annual Approved None Brandon Steffee Export Inspection Report
10 2/23/2022 11:26:01 AM 9/30/2023 12:00:00 AM Re-Inspection Approved None Brandon Steffee Export Inspection Report
10 2/23/2022 11:25:00 AM 3/24/2022 11:25:00 AM Annual Ordered Repaired
  • Any clearance light is missing, cracked, faded, wrong color, or inoperative
  • Any marker light or lens is missing, cracked, faded, wrong color, or inoperative
Brandon Steffee Export Inspection Report
10 3/4/2021 11:39:01 AM 9/30/2022 12:00:00 AM Annual Approved None Rob Hawkins Export Inspection Report
10 2/27/2020 11:15:01 AM 9/30/2021 12:00:00 AM Annual Approved None Jeff Kastenschmidt Export Inspection Report
10 2/13/2019 9:18:01 AM 9/30/2020 12:00:00 AM Annual Approved None Jeff Kastenschmidt Export Inspection Report
10 2/21/2018 10:14:01 AM 9/30/2019 12:00:00 AM Annual Approved None John Pang Export Inspection Report
10 2/16/2017 9:14:01 AM 9/30/2018 12:00:00 AM Annual Approved None John Pang Export Inspection Report
10 1/21/2016 3:45:34 PM 9/30/2017 12:00:00 AM Registration Approved None John Pang Export Inspection Report
10 1/21/2016 9:46:01 AM 9/30/2017 12:00:00 AM Registration Approved None Alex Willis Export Inspection Report
10 3/3/2015 9:04:01 AM 9/30/2016 12:00:00 AM Annual Approved None John Pang Export Inspection Report
10 3/3/2014 11:18:01 AM 9/30/2015 12:00:00 AM Re-Inspection Approved None Alex Willis Export Inspection Report
10 3/3/2014 10:23:00 AM Annual Out of Service
  • The required low air-pressure warning device fails to operate properly
  • Dome light is inoperative.
Alex Willis Export Inspection Report
10 3/7/2013 10:27:01 AM 9/30/2014 12:00:00 AM Re-Inspection Approved None Chris Kath Export Inspection Report
10 3/7/2013 9:05:00 AM 4/5/2013 9:05:00 AM Annual Ordered Repaired
  • Heater motor is not operating properly.
Chris Kath Export Inspection Report
10 2/24/2012 11:00:00 AM 9/30/2013 12:00:00 AM Annual Approved None John Pang Export Inspection Report
Go Back New Search